Field Evaluation of a Portable Multi-Sensor Platform for Characterizing Inter-Individual Variability in Exhaled Breath Responses
Sensors · 2026
DOI: 10.3390/s26206429 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2026. Verfasst von Phillip Olla und 6 weiteren Autor:innen. Beteiligte Einrichtung: Health Services Administration, College of Health Professions, University of Detroit Mercy, Detroit, MI 48221, USA. Hauptthemen laut MEDLINE: Exhalation. Die Arbeit nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: University of Detroit Mercy.
Abstract (Originalsprache)
Portable breath-sensing platforms offer a practical approach for collecting physiological and environmental information outside controlled laboratory settings, but their interpretation is complicated by inter-individual variability and sensor-related effects. This pilot study evaluated the BreathLogix VOC Series prototype, a portable multi-sensor platform incorporating gas-sensitive, carbon-dioxide, temperature, and environmental channels, during routine collegiate athletic activities. A total of 421 breath recordings were obtained from 209 participant ID codes, including 175 pre-exercise and 246 post-exercise recordings. Continuous sensor signals were converted into aggregated sample-level features and analyzed using descriptive statistics, interquartile-range comparisons, Pearson correlation analysis, and K-means clustering. Group-level median responses remained relatively stable across exercise conditions, whereas response variability changed more noticeably. Humidity showed the largest post-exercise increase in dispersion, followed by the hydrogen- and methane-sensitive channels, while the acetone-sensitive response showed reduced variability. Correlation analysis identified strong relationships among selected channels, consistent with possible cross-sensitivity and environmental influence. Clustering revealed two overlapping sensor-derived breath-signature groups primarily separated by acetone-sensitive response; a sex difference in cluster composition was not retained when each participant was counted once. These findings demonstrate the feasibility of field-based multi-channel breath acquisition and highlight the value of variability-centered analysis. Further analytical validation, calibration assessment, and longitudinal reproducibility testing are required.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Health Services Administration, College of Health Professions, University of Detroit Mercy, Detroit, MI 48221, USA.
- Center for Augmenting Intelligence, University of Detroit Mercy, Detroit, MI 48221, USA.
- Department of Electrical & Computer Engineering & Computer Science, University of Detroit Mercy, Detroit, MI 48221, USA.
- London Health Sciences Centre, University of Western Ontario, London, ON N6A 3K7, Canada.
- Cannabix Technologies Inc., 501-3292 Production Way, Burnaby, BC V5A 4R4, Canada.
ORCID-Profile: Ava Travo
Förderung
- University of Detroit Mercy
Zitieren
APA
Olla, P., Shannan, S., Maleki, M., Travo, A., Paknahad, M., Bandi, A., & Favor, N. (2026). Field Evaluation of a Portable Multi-Sensor Platform for Characterizing Inter-Individual Variability in Exhaled Breath Responses. Sensors. https://doi.org/10.3390/s26206429
Vancouver
Olla P, Shannan S, Maleki M, Travo A, Paknahad M, Bandi A, et al. Field Evaluation of a Portable Multi-Sensor Platform for Characterizing Inter-Individual Variability in Exhaled Breath Responses. Sensors. 2026. doi:10.3390/s26206429
BibTeX
@article{Olla2026,
author = {Olla, Phillip and Shannan, Sara and Maleki, Mina and Travo, Ava and Paknahad, Mohammad and Bandi, Ava and Favor, Nina},
title = {Field Evaluation of a Portable Multi-Sensor Platform for Characterizing Inter-Individual Variability in Exhaled Breath Responses},
journal = {Sensors},
year = {2026},
doi = {10.3390/s26206429}
}
EUVIMED