Matrix Effects on the Quantification of NanoLuc Bioluminescence in Ex Vivo Organ Homogenates
Sensors · 2026
DOI: 10.3390/s26196135 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2026. Verfasst von Roman O Melikov und 4 weiteren Autor:innen. Beteiligte Einrichtung: Moscow Center for Advanced Studies, 123592 Moscow, Russia. Hauptthemen laut MEDLINE: Luminescent Measurements, Luciferases, Biosensing Techniques. Die Arbeit nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministry of Science and Higher Education of the Russian Federation, Russian Science Foundation.
Abstract (Originalsprache)
Bioluminescent reporters and biosensors are widely used to quantify gene expression, evaluate delivery systems and assess biodistribution because they provide low-background readouts over a broad dynamic range. The NanoLuc–furimazine system is particularly attractive owing to its high brightness and stability. Ex vivo analysis of organ homogenates offers a controlled approach for measuring tissue-associated reporter activity, yet matrix-dependent effects are often overlooked in quantitative interpretation. Here, we systematically evaluated how mouse organ homogenates affect NanoLuc–furimazine measurements by spiking defined amounts of purified NanoLuc into different organ matrices. Across matrices, optical profiles, blank signals, calibration slopes, and estimated limits of detection and quantification varied, resulting in substantial differences in the measured NanoLuc signal. Further analysis showed that NanoLuc-independent furimazine luminescence arises from lysis-buffer components and protein-containing environments. Matrix-matched blank subtraction reduced background-related bias, whereas matrix-specific calibration demonstrated differences in analytical response, particularly for weak signals and optically dense samples. These findings highlight the extent of matrix-dependent variability in ex vivo NanoLuc measurements and support more accurate interpretation of reporter signals in delivery, biodistribution, biosensing, and gene-expression studies.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Moscow Center for Advanced Studies, 123592 Moscow, Russia.
- Prokhorov General Physics Institute of the Russian Academy of Sciences, 119991 Moscow, Russia.
- Department of Nanobiomedicine, Sirius University of Science and Technology, 354340 Sirius, Russia.
- Shemyakin-Ovchinnikov Institute of Bioorganic Chemistry, Russian Academy of Sciences, 117997 Moscow, Russia.
ORCID-Profile: Roman O Melikov, Alexey V Orlov, Maxim P Nikitin
Förderung
- Ministry of Science and Higher Education of the Russian Federation
- Russian Science Foundation
Zitieren
APA
Melikov, R. O., Samokhina, M. O., Yurchenko, M. A., Orlov, A. V., & Nikitin, M. P. (2026). Matrix Effects on the Quantification of NanoLuc Bioluminescence in Ex Vivo Organ Homogenates. Sensors. https://doi.org/10.3390/s26196135
Vancouver
Melikov RO, Samokhina MO, Yurchenko MA, Orlov AV, Nikitin MP. Matrix Effects on the Quantification of NanoLuc Bioluminescence in Ex Vivo Organ Homogenates. Sensors. 2026. doi:10.3390/s26196135
BibTeX
@article{Melikov2026,
author = {Melikov, Roman O and Samokhina, Maria O and Yurchenko, Maria A and Orlov, Alexey V and Nikitin, Maxim P},
title = {Matrix Effects on the Quantification of NanoLuc Bioluminescence in Ex Vivo Organ Homogenates},
journal = {Sensors},
year = {2026},
doi = {10.3390/s26196135}
}
EUVIMED