Sparse Image Registration-Based Marker-Free Hand Acupoint Localization Using TCM Template Queries
Sensors · 2026
DOI: 10.3390/s26175552 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, 2026. Verfasst von Shujian Zhang und 3 weiteren Autor:innen. Beteiligte Einrichtung: School of Intelligent Systems Engineering, Shenzhen Campus of Sun Yat-sen University, Shenzhen 518107, China. Hauptthemen laut MEDLINE: Hand, Acupuncture Points, Medicine, Chinese Traditional, Image Processing, Computer-Assisted. Die Arbeit nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: the National Key R&D Program of China, the Guangdong Natural Science Foundation, the Shenzhen Science and Technology Program.
Abstract (Originalsprache)
Deep learning for sensor-based medical imaging provides a non-contact and data-driven route for anatomical surface analysis and personalized traditional Chinese medicine (TCM) applications. However, accurate hand-acupoint localization from camera-acquired hand images remains challenging because expert-annotated acupoint datasets are limited and inter-subject anatomical variations are significant. This paper proposes a marker-free hand-acupoint localization method based on deep feature correspondence learning and sparse image registration. The task is formulated as template-to-target correspondence estimation, in which expert-annotated acupoints in a TCM template image are used as query points and mapped to a target hand image acquired by an optical imaging sensor. A Transformer-based architecture is employed to correlate multi-scale image features, and an uncertainty-aware matching formulation is used to estimate both acupoint positions and unreliable matches. Unlike conventional keypoint detection networks, the proposed method exploits TCM template priors and reduces the dependence on dense target-image acupoint annotations. The constructed dataset contains 1400 images from 378 participants. Participant-level partitioning was performed before image-pair generation, yielding a held-out test set of 38 participants (140 images). Palm and dorsal-hand views were evaluated separately against keypoint-detection baselines and COTR. On this participant-independent internal test set, the proposed method achieved AAPE values of 18.42 pixels for palm images and 12.60 pixels for dorsal-hand images, while reducing inference time from 11,000 ms for COTR to 600 ms. These results indicate the feasibility of template-guided image-based hand-acupoint localization with reference to expert annotations.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Intelligent Systems Engineering, Shenzhen Campus of Sun Yat-sen University, Shenzhen 518107, China.
- Guangdong Provincial Key Laboratory of Fire Science and Technology, Guangzhou 510006, China.
ORCID-Profile: Jianqing Peng
Förderung
- the National Key R&D Program of China
- the Guangdong Natural Science Foundation
- the Shenzhen Science and Technology Program
- the University-Industry Collaborative Education Program
- the Guangdong Province Pearl River Leading Talents Program
- the Key-Area Research and Development Program of Guangdong Province
- National Key R&D Program of China
- Guangdong Natural Science Foundation
Zitieren
APA
Zhang, S., Zhang, S., Zhang, C., & Peng, J. (2026). Sparse Image Registration-Based Marker-Free Hand Acupoint Localization Using TCM Template Queries. Sensors. https://doi.org/10.3390/s26175552
Vancouver
Zhang S, Zhang S, Zhang C, Peng J. Sparse Image Registration-Based Marker-Free Hand Acupoint Localization Using TCM Template Queries. Sensors. 2026. doi:10.3390/s26175552
BibTeX
@article{Zhang2026,
author = {Zhang, Shujian and Zhang, Shuyue and Zhang, Chi and Peng, Jianqing},
title = {Sparse Image Registration-Based Marker-Free Hand Acupoint Localization Using TCM Template Queries},
journal = {Sensors},
year = {2026},
doi = {10.3390/s26175552}
}
EUVIMED