Simplified Lead Detection: Graphene-Based Potentiometric Sensors for Pb(II) Monitoring
Sensors · 26.08.2026 · 26 (17) · 5395
DOI: 10.3390/s26175395 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 26.08.2026. Verfasst von Martyna Drużyńska und 2 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Materials Science and Ceramics, AGH University of Krakow, Mickiewicza 30, PL-30059 Krakow, Poland. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: AGH University of Krakow.
Abstract (Originalsprache)
Lead contamination remains a significant environmental and public health concern, creating a demand for analytical platforms that combine sensitivity, simplicity, and long-term stability. In this work, a graphene-containing molecular membrane matrix was developed for the fabrication of single-piece all-solid-state potentiometric sensors for Pb(II) detection. The sensing membrane consisted of poly(vinyl chloride), plasticizers, a Pb(II)-selective ionophore, lipophilic ionic sites, and dispersed graphene nanostructures, forming an integrated molecular sensing interface. Within the membrane phase, selective complexation of Pb(II) ions by the ionophore was coupled with graphene-assisted ion-to-electron transduction, enabling efficient signal generation without the need for a separate solid-contact layer. The influence of graphene incorporation and membrane thickness on sensor performance was systematically investigated. Among the tested configurations, a membrane prepared from 40 µL of sensing cocktail provided the best overall performance, combining high electrical capacitance, favorable surface properties, and superior potential stability. SEM imaging revealed a homogeneous membrane morphology without large graphene agglomerates, indicating effective dispersion of graphene within the polymer matrix. The optimized sensor exhibited a near-Nernstian slope of 30.3 mV dec−1, a linear response range from 1.0 × 10−7 to 1.0 × 10−2 M, a detection limit of 6.3 × 10−8 M, and a potential drift of only 0.35 mV h−1. These results demonstrate that direct incorporation of graphene into an ion-selective membrane is an effective strategy for constructing robust and scalable single-piece potentiometric sensors for Pb(II) monitoring and highlight the potential of developed membrane materials for electrochemical sensing applications.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Faculty of Materials Science and Ceramics, AGH University of Krakow, Mickiewicza 30, PL-30059 Krakow, Poland.
ORCID-Profile: Martyna Drużyńska, Nikola Lenar, Beata Paczosa-Bator
Förderung
- AGH University of Krakow
Zitieren
APA
Drużyńska, M., Lenar, N., & Paczosa-Bator, B. (2026). Simplified Lead Detection: Graphene-Based Potentiometric Sensors for Pb(II) Monitoring. Sensors, 26(17), 5395. https://doi.org/10.3390/s26175395
Vancouver
Drużyńska M, Lenar N, Paczosa-Bator B. Simplified Lead Detection: Graphene-Based Potentiometric Sensors for Pb(II) Monitoring. Sensors. 2026;26(17):5395. doi:10.3390/s26175395
BibTeX
@article{Druyska2026,
author = {Drużyńska, Martyna and Lenar, Nikola and Paczosa-Bator, Beata},
title = {Simplified Lead Detection: Graphene-Based Potentiometric Sensors for Pb(II) Monitoring},
journal = {Sensors},
year = {2026},
volume = {26},
number = {17},
pages = {5395},
doi = {10.3390/s26175395}
}