Robust Monocular Human Height Estimation via a Temporal SegPose Framework and Three-Way Orthogonal Playground Calibration
Sensors · 19.08.2026 · 26 (16) · 5252
DOI: 10.3390/s26165252 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 19.08.2026. Verfasst von Yudong Cheng. Beteiligte Einrichtung: Department of Electrical and Computer Engineering, Concordia University, Montreal, QC H3G 1M8, Canada. Hauptthemen laut MEDLINE: Body Height. Die Arbeit nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Accurate non-contact human height estimation is vital for large-scale growth monitoring in schools but remains challenging for monocular RGB sensors due to scale ambiguity and keypoint jitter. This study proposes a robust temporal SegPose framework for high-precision height measurement in unconstrained outdoor playground environments. We develop a multi-task deep learning model using a MobileNetV4 backbone and a novel Height-Aware Boundary Refinement (HABR) module, which utilizes nose-spatial priors to refine cranial vertex localization. To resolve scale issues, a three-way orthogonal calibration system is established using existing playground marking lines and goalposts to dynamically estimate ground plane metric factors. A linear Kalman filter is integrated to smooth keypoint trajectories, suppressing gait-induced oscillations and reducing high-frequency jitter by 64.92%. Validated on a dataset of 95 volunteers (53 males, 42 females) at distances of 6–12 m, the proposed system achieves a mean absolute error (MAE) of 1.42 cm and a mean absolute percentage error (MAPE) of 0.84%, significantly outperforming recent Transformer-based state-of-the-art methods. The framework operates at 42.7 FPS, ensuring real-time performance while adhering to a privacy-preserving protocol that decouples biometric records from individual identities. These results demonstrate that our framework effectively overcomes boundary ambiguity and distance-dependent resolution loss, providing a reliable, efficient, and ethical solution for automated physical health assessments in educational settings.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Electrical and Computer Engineering, Concordia University, Montreal, QC H3G 1M8, Canada.
ORCID-Profile: Yudong Cheng
Zitieren
APA
Cheng, Y. (2026). Robust Monocular Human Height Estimation via a Temporal SegPose Framework and Three-Way Orthogonal Playground Calibration. Sensors, 26(16), 5252. https://doi.org/10.3390/s26165252
Vancouver
Cheng Y. Robust Monocular Human Height Estimation via a Temporal SegPose Framework and Three-Way Orthogonal Playground Calibration. Sensors. 2026;26(16):5252. doi:10.3390/s26165252
BibTeX
@article{Cheng2026,
author = {Cheng, Yudong},
title = {Robust Monocular Human Height Estimation via a Temporal SegPose Framework and Three-Way Orthogonal Playground Calibration},
journal = {Sensors},
year = {2026},
volume = {26},
number = {16},
pages = {5252},
doi = {10.3390/s26165252}
}
EUVIMED