EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Long-Term Validation of a Consumer- vs. Industrial-Grade Indoor Radon and Air Quality Monitor at a School in Utah

John D Beard iD, Maren M Ball, Christopher Kitras iD, Philip B Lundrigan iD

Sensors · 18.08.2026 · 26 (16) · 5230

DOI: 10.3390/s26165230 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 18.08.2026. Verfasst von John D Beard und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Public Health, Brigham Young University, Provo, UT 84602, USA. Die Arbeit nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIOSH CDC HHS, National Institute for Occupational Safety and Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In recent years, the demand for indoor radon and air quality monitors has increased while more affordable consumer-grade monitors have become available. The aim of our study was to assess the validity of the less expensive, non-calibrated, consumer-grade Lüft (SunRADON LLC, Melbourne, FL, USA) compared to the more expensive, annually and manufacturer calibrated, industrial-grade Model 1028 XP (SunRADON LLC, Melbourne, FL, USA). We collected data about 24 h moving averages of barometric pressure, carbon dioxide (CO2), radon, relative humidity, temperature, and volatile organic compounds (VOC) for approximately 29 weeks in 2024 in each of six rooms in a school in Utah. The mean difference in the co-located Lüfts’ and Model 1028 XPs’ 24 h moving average radon was −0.05 pCi/L of air (95% confidence interval: −0.24, 0.14, p = 0.50) and the concordance correlation coefficient (CCC) was 0.92. The Lüfts’ and Model 1028 XPs’ 24 h moving averages were similar for barometric pressure (CCC: 0.87), but the Lüfts’ 24 h moving averages were lower than the Model 1028 XPs’ for CO2, relative humidity, and VOC and higher for temperature. The Lüft provided valid measurements of 24 h moving averages for barometric pressure and radon, but not for CO2, relative humidity, temperature, and VOC.

Schlagwörter

Stichwörter der Autor:innen

barometric pressurecarbon dioxideindoor air qualitymonitorradonrelative humidityschooltemperaturevalidationvolatile organic compounds

Autor:innen und Institutionen

  • Department of Public Health, Brigham Young University, Provo, UT 84602, USA.
  • Department of Electrical and Computer Engineering, Brigham Young University, Provo, UT 84602, USA.

ORCID-Profile: John D Beard, Christopher Kitras, Philip B Lundrigan

Förderung

  • NIOSH CDC HHS
  • National Institute for Occupational Safety and Health

Zitieren

APA

Beard, J. D., Ball, M. M., Kitras, C., & Lundrigan, P. B. (2026). Long-Term Validation of a Consumer- vs. Industrial-Grade Indoor Radon and Air Quality Monitor at a School in Utah. Sensors, 26(16), 5230. https://doi.org/10.3390/s26165230

Vancouver

Beard JD, Ball MM, Kitras C, Lundrigan PB. Long-Term Validation of a Consumer- vs. Industrial-Grade Indoor Radon and Air Quality Monitor at a School in Utah. Sensors. 2026;26(16):5230. doi:10.3390/s26165230

BibTeX
@article{Beard2026,
  author = {Beard, John D and Ball, Maren M and Kitras, Christopher and Lundrigan, Philip B},
  title = {Long-Term Validation of a Consumer- vs. Industrial-Grade Indoor Radon and Air Quality Monitor at a School in Utah},
  journal = {Sensors},
  year = {2026},
  volume = {26},
  number = {16},
  pages = {5230},
  doi = {10.3390/s26165230}
}
Kostenlos starten →