A Head-to-Head Comparison of Three Literature Algorithms for Physical Activity Endpoints from a Wrist Accelerometer in Free-Living Conditions
Sensors · 17.08.2026 · 26 (16) · 5194
DOI: 10.3390/s26165194 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Sensors, online erschienen am 17.08.2026. Verfasst von Nunzio Camerlingo und 4 weiteren Autor:innen. Beteiligte Einrichtung: Pfizer Research and Development, Cambridge, MA 02139, USA. Hauptthemen laut MEDLINE: Accelerometry, Algorithms, Wrist, Exercise. Die Arbeit nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Pfizer.
Abstract (Originalsprache)
Wrist accelerometers are widely used in clinical trials for continuous assessment of participants’ day-to-day physical activity and function, through derivation of metrics such as time spent in sedentary, non-sedentary, light, and moderate-to-vigorous physical activity (MVPA). Multiple algorithms have been proposed to derive these physical activity endpoints; however, the agreement across the endpoints derived from these algorithms has not been thoroughly explored. In this work, we leverage a publicly available dataset, CAPTURE-24, including wrist accelerometer data and experts’ annotations of various physical activities for 151 healthy adults, monitored at-home for one day, to compare three literature algorithms: Algorithm #1, SciKit Digital Health (SKDH), from Adamowicz et al., Algorithm #2 from Staudenmayer et al., and Algorithm #3 from Montoye et al. Algorithms’ outputs were assessed against experts’ annotations via paired t-tests, Pearson’s correlation (R), Bland–Altman analysis, accuracy, sensitivity, specificity, and F1-score. Algorithm #1 and Algorithm #2 showed stronger correlation and lower bias with experts’ annotations for time in sedentary (Algorithm #1: R = 0.91), and MVPA (Algorithm #1: R = 0.63), compared to Algorithm #3. In addition, Algorithm #1 and Algorithm #3 outperformed Algorithm #2 for time in light activity. Future work using longer monitoring periods and reference calorimetry devices should be performed to confirm the reproducibility of these findings.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Pfizer Research and Development, Cambridge, MA 02139, USA.
- Department of Biostatistics, Johns Hopkins Bloomberg School of Public Health, Baltimore, MD 21205, USA.
ORCID-Profile: Nunzio Camerlingo, Lily Koffman, Lukas Adamowicz
Förderung
- Pfizer
Zitieren
APA
Camerlingo, N., Koffman, L., Adamowicz, L., Moustridi, E., & Karahanoglu, F. I. (2026). A Head-to-Head Comparison of Three Literature Algorithms for Physical Activity Endpoints from a Wrist Accelerometer in Free-Living Conditions. Sensors, 26(16), 5194. https://doi.org/10.3390/s26165194
Vancouver
Camerlingo N, Koffman L, Adamowicz L, Moustridi E, Karahanoglu FI. A Head-to-Head Comparison of Three Literature Algorithms for Physical Activity Endpoints from a Wrist Accelerometer in Free-Living Conditions. Sensors. 2026;26(16):5194. doi:10.3390/s26165194
BibTeX
@article{Camerlingo2026,
author = {Camerlingo, Nunzio and Koffman, Lily and Adamowicz, Lukas and Moustridi, Evgenia and Karahanoglu, Fikret Isik},
title = {A Head-to-Head Comparison of Three Literature Algorithms for Physical Activity Endpoints from a Wrist Accelerometer in Free-Living Conditions},
journal = {Sensors},
year = {2026},
volume = {26},
number = {16},
pages = {5194},
doi = {10.3390/s26165194}
}
EUVIMED