Study on the Influence of Rotation Axis Misalignment of the Exoskeleton Knee Joint on Human Knee Joint Torque
Sensors · 12.08.2026 · 26 (16) · 5119
DOI: 10.3390/s26165119 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 12.08.2026. Verfasst von Changlong Jiang und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering, Nanjing University of Science and Technology, Nanjing 210094, China. Hauptthemen laut MEDLINE: Knee Joint, Exoskeleton Device. Die Arbeit nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Misalignment between the rotation axis of a lower-limb exoskeleton knee joint and the human knee joint in the sagittal plane introduces additional human-exoskeleton interaction forces, affecting gait and assistance efficiency. This study proposes an equivalent stiffness-damping scheme that simultaneously accounts for the serial characteristics of both the exoskeleton’s strapping and human soft tissues, and establishes a human-exoskeleton coupling model based on OpenSim that allows for precise adjustment of the misalignment magnitude along the sagittal coordinate system. Simulation results indicate that the effects of misalignment exhibit significant directional dependence: at a misalignment of 0.05 m, the peak increase in extension torque in the positive y-axis direction reached 38.9%, while the peak increase in flexion torque in the negative x-axis direction reached 211.2%. The trends in human-exoskeleton interaction torque and electromyographic signals measured experimentally were consistent with the simulation results. Considering that, at a misalignment of 0.02 m, the maximum difference in torque in the negative x-axis direction was 54.65% and the assist efficiency in the positive x-axis direction dropped to −5.13%, it is recommended that the misalignment of the exoskeleton knee joint be controlled within 0.02 m. This provides quantitative evidence for the structural design and wear calibration of the exoskeleton.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Mechanical Engineering, Nanjing University of Science and Technology, Nanjing 210094, China.
- Zhiyuan Research Institute, Hangzhou 310000, China.
ORCID-Profile: Changlong Jiang, Xiaorong Guan
Zitieren
APA
Jiang, C., Guan, X., Wang, Z., Li, D., & He, L. (2026). Study on the Influence of Rotation Axis Misalignment of the Exoskeleton Knee Joint on Human Knee Joint Torque. Sensors, 26(16), 5119. https://doi.org/10.3390/s26165119
Vancouver
Jiang C, Guan X, Wang Z, Li D, He L. Study on the Influence of Rotation Axis Misalignment of the Exoskeleton Knee Joint on Human Knee Joint Torque. Sensors. 2026;26(16):5119. doi:10.3390/s26165119
BibTeX
@article{Jiang2026,
author = {Jiang, Changlong and Guan, Xiaorong and Wang, Zheng and Li, Dingzhe and He, Long},
title = {Study on the Influence of Rotation Axis Misalignment of the Exoskeleton Knee Joint on Human Knee Joint Torque},
journal = {Sensors},
year = {2026},
volume = {26},
number = {16},
pages = {5119},
doi = {10.3390/s26165119}
}