EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Validity of the CORE Wearable Sensor During Internal Cooling Induced by Hyperhydration with Cold Water at Rest

Eric D B Goulet iD, Antoine Jolicoeur Desroches iD, Thomas A Deshayes iD, Timothée Pancrate iD, Marc Elouann Pidoux, Antoine Carmichael, Tristan Etienne

Sensors · 08.08.2026 · 26 (16) · 5042

DOI: 10.3390/s26165042 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 08.08.2026. Verfasst von Eric D B Goulet und 6 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Physical Activity Sciences, University of Sherbrooke, Sherbrooke, QC J1K 2R1, Canada. Hauptthemen laut MEDLINE: Wearable Electronic Devices, Water. Die Arbeit nennt 63 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Université de Sherbrooke, University of Sherbrooke.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Pre-exercise internal cooling through cold-water-induced hyperhydration may attenuate increases in core body temperature (TC) and improve endurance performance. Quantifying the extent of reduction in TC induced by hyperhydration is important for optimizing its timing before exercise. We compared TC values obtained from a wearable sensor, the CORE, with those of a gastrointestinal temperature telemetric sensor (GTS) during hyperhydration. Eleven participants (two women; age: 24 ± 4 yrs) completed a 120 min seated period where they consumed, over the first 60 min, four boluses of 4 °C water (7.5 mL · kg fat-free mass [FFM]−1), each containing 0.35 g · kg FFM−1 of glycerol. Measures of TC were taken every 20 min with both sensors. According to the GTS, hyperhydration induced a peak TC decline of −0.76 ± 0.31 °C at min 60; at this time, the change in TC from baseline estimated by the CORE was −0.09 °C ± 0.20 °C. The greatest decline in TC detected by the CORE was −0.11 ± 0.19 °C. Bland and Altman analyses revealed that average TC declines of –0.1, −0.2, −0.3, −0.4, −0.5 and −0.6 °C from baseline were associated with TC values estimated by the CORE that were respectively +0.29, +0.41, +0.57, +0.65, +0.77 and +0.89 °C higher than the GTS. An intraclass correlation coefficient of 0.12 suggested poor agreement between instruments. These results raise concerns about the ability of the CORE to detect changes in TC induced by a hyperhydration protocol generating a substantial heat sink.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Wearable Electronic DevicesWaterHumansFemaleCold TemperatureBody TemperatureAdultRestYoung Adult

Stichwörter der Autor:innen

cold water ingestionexerciseheat flux sensorsheat stresspre-exercise coolingwearable sensors

Substanzen

Water

Autor:innen und Institutionen

  • Faculty of Physical Activity Sciences, University of Sherbrooke, Sherbrooke, QC J1K 2R1, Canada.
  • Performance, Hydration and Thermoregulation (PHT) Laboratory, University of Sherbrooke, Sherbrooke, QC J1K 2R1, Canada.
  • Research Centre on Aging, University of Sherbrooke, Sherbrooke, QC J1H 4C4, Canada.

ORCID-Profile: Eric D B Goulet, Antoine Jolicoeur Desroches, Thomas A Deshayes, Timothée Pancrate

Förderung

  • Université de Sherbrooke
  • University of Sherbrooke

Zitieren

APA

Goulet, E. D. B., Desroches, A. J., Deshayes, T. A., Pancrate, T., Pidoux, M. E., Carmichael, A., & Etienne, T. (2026). Validity of the CORE Wearable Sensor During Internal Cooling Induced by Hyperhydration with Cold Water at Rest. Sensors, 26(16), 5042. https://doi.org/10.3390/s26165042

Vancouver

Goulet EDB, Desroches AJ, Deshayes TA, Pancrate T, Pidoux ME, Carmichael A, et al. Validity of the CORE Wearable Sensor During Internal Cooling Induced by Hyperhydration with Cold Water at Rest. Sensors. 2026;26(16):5042. doi:10.3390/s26165042

BibTeX
@article{Goulet2026,
  author = {Goulet, Eric D B and Desroches, Antoine Jolicoeur and Deshayes, Thomas A and Pancrate, Timothée and Pidoux, Marc Elouann and Carmichael, Antoine and Etienne, Tristan},
  title = {Validity of the CORE Wearable Sensor During Internal Cooling Induced by Hyperhydration with Cold Water at Rest},
  journal = {Sensors},
  year = {2026},
  volume = {26},
  number = {16},
  pages = {5042},
  doi = {10.3390/s26165042}
}
Kostenlos starten →