Limitations of Environmental Extrapolation in Low-Cost Carbon Monoxide and Fine Particulate Matter Sensors
Sensors · 06.08.2026 · 26 (15) · 4988
DOI: 10.3390/s26154988 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 06.08.2026. Verfasst von Sean Benjamin und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering, University of Colorado at Boulder, Boulder, CO 80301, USA. Die Arbeit nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: U.S. National Science Foundation.
Abstract (Originalsprache)
Low-cost air quality sensors have grown in popularity. Calibrating these sensors in environments that perfectly mirror the environments they will be used in is difficult and can be costly, so researchers often need to extrapolate calibration models outside of the environmental and pollutant data ranges they are trained on. As such, understanding the impact that this extrapolation has on the resulting measurements is important when using this data. In this study we conducted a multi-season colocation between two low-cost sensors (Plantower PMS5003 for PM2.5 and Alphasense CO-B4 for CO) and Federal Equivalence Method monitors. We then trained multiple calibration models on different selective ranges of relative humidity, temperature, and pollutant concentration data to test how those models performed when extrapolated into data ranges. There were three main takeaways in this study. First, there was minimal bias error in calibration model performance when a model is applied to data that falls within its training data range. Second, extrapolating models into data that was outside of their training data ranges led to increases in bias error. Third, extrapolating models into higher pollutant concentrations than what the models were trained on increases random error.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Mechanical Engineering, University of Colorado at Boulder, Boulder, CO 80301, USA.
- Department of Environmental Engineering, University of Colorado at Boulder, Boulder, CO 80303, USA.
ORCID-Profile: Evan R Coffey
Förderung
- U.S. National Science Foundation
Zitieren
APA
Benjamin, S., Coffey, E. R., Frischmon, C., & Hannigan, M. (2026). Limitations of Environmental Extrapolation in Low-Cost Carbon Monoxide and Fine Particulate Matter Sensors. Sensors, 26(15), 4988. https://doi.org/10.3390/s26154988
Vancouver
Benjamin S, Coffey ER, Frischmon C, Hannigan M. Limitations of Environmental Extrapolation in Low-Cost Carbon Monoxide and Fine Particulate Matter Sensors. Sensors. 2026;26(15):4988. doi:10.3390/s26154988
BibTeX
@article{Benjamin2026,
author = {Benjamin, Sean and Coffey, Evan R and Frischmon, Caroline and Hannigan, Michael},
title = {Limitations of Environmental Extrapolation in Low-Cost Carbon Monoxide and Fine Particulate Matter Sensors},
journal = {Sensors},
year = {2026},
volume = {26},
number = {15},
pages = {4988},
doi = {10.3390/s26154988}
}
EUVIMED