EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

STV-FSANet: Track-Level Spatio-Temporal Verification for Fire and Smoke Alarm Validation in Video Surveillance

Deepak Ghimire iD, Donghoon Kim iD, Yeonho Jo iD, Eunhee Lee, Sunghwan Jeong, Byoungjun Kim iD

Sensors · 05.08.2026 · 26 (15) · 4970

DOI: 10.3390/s26154970 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 05.08.2026. Verfasst von Deepak Ghimire und 5 weiteren Autor:innen. Beteiligte Einrichtung: AI Application Research Center, Korea Electronics Technology Institute, Jeonju 54853, Republic of Korea. Die Arbeit nennt 51 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Korea Forest Service.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Generating early and reliable fire/smoke alarms from real-world video surveillance remains challenging because visually ambiguous patterns such as sunlight, reflections, clouds, mist, steam, and illumination changes often trigger unstable frame-level false alarms. This paper presents the Spatio-Temporal Verification Network for Fire and Smoke Alarm Validation (STV-FSANet), a detect–track–verify framework that first localizes candidate fire/smoke regions, associates them into temporal tracks, and then verifies the observed sequence of each active track online as fire, smoke, or false fire/smoke. The verifier combines a primary appearance stream from cropped candidate regions with lightweight geometric cues derived from bounding-box position, scale, motion, and short-term fluctuation. A dual-branch GRU models long-term track history, while recent temporal pooling emphasizes newly observed evidence for streaming decisions. To support temporal learning, we construct the Fire–Smoke Alarm Verification (FSAV) Tracklet Dataset from 1347 source videos, yielding 58,733 parent tracks and 2.06 million annotated track frames. The best matched-context STV-FSANet achieves 97.09% test accuracy and 95.81% macro-F1, and both shorter-context models are within 0.5 percentage points of their final prefix metrics by 1.0 s. The results indicate that compact temporal evidence is more useful than simply accumulating longer 96-frame histories. The proposed model also rejects false fire/smoke tracklets with 90.2% recall, demonstrating the value of explicit hard-negative modeling, while the decoupled design allows the verifier to be reused with future detector backbones. TensorRT FP16 deployment reaches 109.55 frames/s on an RTX 4060 Laptop GPU and 39.51 frames/s on a Jetson AGX Orin DevKit.

Schlagwörter

Stichwörter der Autor:innen

GRUfalse alarm suppressionfire detectionrecurrent neural networksmoke detectiontemporal verificationtrack-based analysisvideo surveillance

Autor:innen und Institutionen

  • AI Application Research Center, Korea Electronics Technology Institute, Jeonju 54853, Republic of Korea.

ORCID-Profile: Deepak Ghimire, Donghoon Kim, Yeonho Jo, Byoungjun Kim

Förderung

  • Korea Forest Service

Zitieren

APA

Ghimire, D., Kim, D., Jo, Y., Lee, E., Jeong, S., & Kim, B. (2026). STV-FSANet: Track-Level Spatio-Temporal Verification for Fire and Smoke Alarm Validation in Video Surveillance. Sensors, 26(15), 4970. https://doi.org/10.3390/s26154970

Vancouver

Ghimire D, Kim D, Jo Y, Lee E, Jeong S, Kim B. STV-FSANet: Track-Level Spatio-Temporal Verification for Fire and Smoke Alarm Validation in Video Surveillance. Sensors. 2026;26(15):4970. doi:10.3390/s26154970

BibTeX
@article{Ghimire2026,
  author = {Ghimire, Deepak and Kim, Donghoon and Jo, Yeonho and Lee, Eunhee and Jeong, Sunghwan and Kim, Byoungjun},
  title = {STV-FSANet: Track-Level Spatio-Temporal Verification for Fire and Smoke Alarm Validation in Video Surveillance},
  journal = {Sensors},
  year = {2026},
  volume = {26},
  number = {15},
  pages = {4970},
  doi = {10.3390/s26154970}
}
Kostenlos starten →