Experimental Validation of a Compact and Versatile Bioimpedance Measurement Platform Based on the SENSIPLUS Chip
Sensors · 04.08.2026 · 26 (15) · 4922
DOI: 10.3390/s26154922 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 04.08.2026. Verfasst von Lorenzo Giannini und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Information Engineering, Electronics and Telecommunications, Sapienza University of Rome, 00184 Rome, Italy. Hauptthemen laut MEDLINE: Electric Impedance, Biosensing Techniques. Die Arbeit nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Union, European Union Horizon Europe program.
Abstract (Originalsprache)
The growing demand for wearable and Internet of Medical Things (IoMT) devices is driving the development of compact, low-power platforms for continuous physiological monitoring. Bioimpedance analysis represents a versatile non-invasive technique for the assessment of tissue properties, body composition, and respiratory dynamics. This work presents a comprehensive experimental validation of a compact bioimpedance measurement platform based on the SENSIPLUS chip, a CMOS sensor interface integrating a frequency-programmable lock-in amplifier for Electrochemical Impedance Spectroscopy in the 10 kHz–1 MHz range. The platform was validated at three complementary levels: (i) electrical characterization on Debye tissue-equivalent circuits using a three-point bilinear calibration, with analysis of the electrode–skin contribution and repeatability assessment; (ii) in vivo multi-frequency bioimpedance spectroscopy (BIS) with Cole–Cole model fitting and hook-effect correction; and (iii) single-frequency thoracic impedance plethysmography for respiratory monitoring. Results were compared against an Agilent E4980A precision Inductance (L), Capacitance (C), and Resistance (R) meter and a calibrated spirometer. The presented device achieved a maximum resistance error below 5.7% and reactance deviation under 6 Ω across the investigated frequency range, Cole–Cole parameters consistent with reference values, and strong linear correlation (R2=0.97) between thoracic impedance variations and tidal volume, with respiratory rate estimation errors below 2% across the ten sessions, specifically 1.43% during normal breathing and 1.96% during deep breathing. These results demonstrate that the SENSIPLUS-based platform achieves metrological performance compatible with the requirements of wearable IoMT applications, here demonstrated in a single-subject proof-of-concept study, while relying for all critical analog functions on a compact (1.5×1.5) mm2 system-on-chip with low power consumption (1.5 mW).
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Information Engineering, Electronics and Telecommunications, Sapienza University of Rome, 00184 Rome, Italy.
- Interdisciplinary Department of Wellbeing, Health and Environmental Sustainability, Sapienza University of Rome, 02100 Rieti, Italy.
- Sensichips s.r.l., 04011 Aprilia, Italy.
- Department of Information Engineering, University of Pisa, 56100 Pisa, Italy.
ORCID-Profile: Lorenzo Giannini, Rita Asquini, Alessio Buzzin, Paolo Bruschi, Emanuele Piuzzi
Förderung
- European Union
- European Union Horizon Europe program
Zitieren
APA
Giannini, L., Asquini, R., Buzzin, A., Contardi, S., Bruschi, P., & Piuzzi, E. (2026). Experimental Validation of a Compact and Versatile Bioimpedance Measurement Platform Based on the SENSIPLUS Chip. Sensors, 26(15), 4922. https://doi.org/10.3390/s26154922
Vancouver
Giannini L, Asquini R, Buzzin A, Contardi S, Bruschi P, Piuzzi E. Experimental Validation of a Compact and Versatile Bioimpedance Measurement Platform Based on the SENSIPLUS Chip. Sensors. 2026;26(15):4922. doi:10.3390/s26154922
BibTeX
@article{Giannini2026,
author = {Giannini, Lorenzo and Asquini, Rita and Buzzin, Alessio and Contardi, Simone and Bruschi, Paolo and Piuzzi, Emanuele},
title = {Experimental Validation of a Compact and Versatile Bioimpedance Measurement Platform Based on the SENSIPLUS Chip},
journal = {Sensors},
year = {2026},
volume = {26},
number = {15},
pages = {4922},
doi = {10.3390/s26154922}
}