EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Research on Stress–Strain Detection in Iron Specimens Using DIC and ACSM Techniques

Guangyong Yang, Zijing Chen, Zhengqiang Lei, Rui Li, Yanbing Wang

Sensors · 31.07.2026 · 26 (15) · 4834

DOI: 10.3390/s26154834 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 31.07.2026. Verfasst von Guangyong Yang und 4 weiteren Autor:innen. Beteiligte Einrichtung: PipeChina Institute of Science and Technology, Tianjin 300450, China. Die Arbeit nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: PipeChina, PipeChina Directed Research Project.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Stress–strain detection serves as a common inspection technique in engineering integrity management, enabling the prediction of the health status and remaining service life of materials or structures. This study systematically investigates the performance and application effectiveness of Digital Image Correlation (DIC) and Alternating Current Stress Measurement (ACSM) technologies in the field of stress–strain detection. Based on the inverse magnetostriction effect and Maxwell’s equations, an ACSM detection system was developed, achieving the conversion of stress signals into electromagnetic signals. Simultaneously, DIC technology combined with a high-resolution binocular vision system was employed to realize non-contact measurement of full-field strain distribution. Finite element analysis using COMSOL V6.1 software was conducted to simulate the stress–strain distribution of ferrous specimens under axial tensile load, identifying the range of the gauge section with uniform stress–strain distribution. An experimental platform was established to perform tensile tests on flat specimens. The results demonstrated that the stress detection error of the ACSM system was less than 42.93 MPa, the strain measurement error of the DIC system was below 2.14722 × 10−4, and the stress inversion error was less than 31 MPa. A comprehensive comparison indicates that DIC technology offers superior performance in measurement accuracy and resolution, while ACSM technology provides advantages in operational convenience and rapid response, making it suitable for rapid screening in industrial settings.

Schlagwörter

Stichwörter der Autor:innen

ACSMCOMSOLDICNDTinverse magnetostrictionstrainstress

Autor:innen und Institutionen

  • PipeChina Institute of Science and Technology, Tianjin 300450, China.
  • China University of Petroleum (Beijing), Beijing 102249, China.

Förderung

  • PipeChina
  • PipeChina Directed Research Project

Zitieren

APA

Yang, G., Chen, Z., Lei, Z., Li, R., & Wang, Y. (2026). Research on Stress–Strain Detection in Iron Specimens Using DIC and ACSM Techniques. Sensors, 26(15), 4834. https://doi.org/10.3390/s26154834

Vancouver

Yang G, Chen Z, Lei Z, Li R, Wang Y. Research on Stress–Strain Detection in Iron Specimens Using DIC and ACSM Techniques. Sensors. 2026;26(15):4834. doi:10.3390/s26154834

BibTeX
@article{Yang2026,
  author = {Yang, Guangyong and Chen, Zijing and Lei, Zhengqiang and Li, Rui and Wang, Yanbing},
  title = {Research on Stress–Strain Detection in Iron Specimens Using DIC and ACSM Techniques},
  journal = {Sensors},
  year = {2026},
  volume = {26},
  number = {15},
  pages = {4834},
  doi = {10.3390/s26154834}
}
Kostenlos starten →