An Intelligent Multi-Emissivity Infrared Temperature Correction Method for Substation Equipment Based on Semantic Segmentation
Sensors · 27.07.2026 · 26 (15) · 4754
DOI: 10.3390/s26154754 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 27.07.2026. Verfasst von Sheng Han und 3 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Cleaner Intelligent Control on Coal & Electricity, Taiyuan University of Technology, Taiyuan 030600, China. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Fundamental Research Program of Shanxi Province, Development Program of Shanxi Province, Key Laboratory Fund of Clean and Intelligent Control of Coal-fired Power, Ministry of Education.
Abstract (Originalsprache)
Emissivity is a critical parameter in infrared temperature measurement and varies significantly among different materials. Infrared thermography has been widely used for the inspection of substation equipment. However, substations contain a large number of devices with complex structures, making it impractical to assign a separate emissivity value to each device or component. This limitation can significantly affect temperature measurement accuracy. To address this issue, this paper proposes an intelligent multi-emissivity temperature correction method for infrared images of substation equipment. First, a temperature–emissivity correction function is established. Then, a total of 2189 infrared images of substation equipment are collected, and the main equipment components are annotated at the pixel level. Subsequently, an equipment component segmentation model based on DeepLabv3+ is trained. Finally, different emissivity values are assigned to different component regions for temperature correction, and corrected infrared pseudo-color images are regenerated. In the experiment, the temperature values before and after correction are compared with thermocouple measurements. In the present validation experiment, the average deviation between the corrected infrared temperature and the thermocouple measurement was reduced by 79.2% compared with that before correction.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Key Laboratory of Cleaner Intelligent Control on Coal & Electricity, Taiyuan University of Technology, Taiyuan 030600, China.
- State Key Laboratory of Disaster Prevention & Reduction for Power Grid, Changsha University of Science and Technology, Changsha 410114, China.
ORCID-Profile: Sheng Han
Förderung
- Fundamental Research Program of Shanxi Province
- Development Program of Shanxi Province
- Key Laboratory Fund of Clean and Intelligent Control of Coal-fired Power, Ministry of Education
- Key Research and Development Program of Shanxi Province
Zitieren
APA
Han, S., Dong, J., Huang, Y., & Zhang, B. (2026). An Intelligent Multi-Emissivity Infrared Temperature Correction Method for Substation Equipment Based on Semantic Segmentation. Sensors, 26(15), 4754. https://doi.org/10.3390/s26154754
Vancouver
Han S, Dong J, Huang Y, Zhang B. An Intelligent Multi-Emissivity Infrared Temperature Correction Method for Substation Equipment Based on Semantic Segmentation. Sensors. 2026;26(15):4754. doi:10.3390/s26154754
BibTeX
@article{Han2026,
author = {Han, Sheng and Dong, Jialong and Huang, Yafei and Zhang, Baifu},
title = {An Intelligent Multi-Emissivity Infrared Temperature Correction Method for Substation Equipment Based on Semantic Segmentation},
journal = {Sensors},
year = {2026},
volume = {26},
number = {15},
pages = {4754},
doi = {10.3390/s26154754}
}
EUVIMED