A Modified Single Metamaterial Split-Ring Resonator for Enhanced Sensitivity

Amal Swileh, Rola Saad iD, Salam K Khamas iD

Sensors · 22.07.2026 · 26 (14) · 4659

DOI: 10.3390/s26144659 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 22.07.2026. Verfasst von Amal Swileh und 2 weiteren Autor:innen. Beteiligte Einrichtung: School of Electrical and Electronic Engineering, University of Sheffield, Sheffield S10 2TN, UK. Die Arbeit nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A novel microwave biosensor operating in the C-band is developed and characterised for enhanced glucose sensing applications. The sensor is based on a single metamaterial asymmetric split-ring resonator (SASR) and has been investigated in two configurations: a single semi-circular design (SASR-S) and a double semi-circular design (SASR-D). The structural modifications were introduced to enlarge the sensing area by creating two high-field hotspots, thereby increasing the interaction between the electromagnetic (EM) field and the sample, which consequently enhances the overall sensor sensitivity. The sensor is fabricated on a Rogers AD350A substrate and is optimised to detect glucose levels in a 1 µL solution applied within each semi-circle sensing region. To characterise the sensor’s enhanced sensitivity, we performed a 3D electromagnetic simulation of a small droplet positioned within a semicircular sensing region, varying the relative permittivity of the droplet from 45 to 65. The resulting shifts in resonant frequency served as a primary indicator of dielectric sensitivity. The sensor’s response was experimentally validated using a vector network analyser to measure the transmission coefficient (S21) of samples with no glucose and at glucose concentrations of 97 mg/dL to 286 mg/dL. The results demonstrate that the resonator configuration strongly influences the resonance frequency shift and sensitivity, with the SASR-D configuration being the most effective design. This has also been confirmed by measurements demonstrating a sensitivity of approximately 2.4 MHz/(mg/dL), representing an approximately two-fold improvement over the SASR-S sensor (sensitivity: 1.27 MHz/(mg/dL)) and a notable enhancement over previously reported sensors. These findings demonstrate the practical potential of the proposed sensor for blood glucose monitoring applications.

Schlagwörter

Stichwörter der Autor:innen

CSTasymmetric split resonatorglucose levelmetamaterialmicrowave sensingrectangular waveguide

Autor:innen und Institutionen

  • School of Electrical and Electronic Engineering, University of Sheffield, Sheffield S10 2TN, UK.
  • Medical Physics and Biomedical Engineering, University College London, London WC1E 6BT, UK.

ORCID-Profile: Rola Saad, Salam K Khamas

Zitieren

APA

Swileh, A., Saad, R., & Khamas, S. K. (2026). A Modified Single Metamaterial Split-Ring Resonator for Enhanced Sensitivity. Sensors, 26(14), 4659. https://doi.org/10.3390/s26144659

Vancouver

Swileh A, Saad R, Khamas SK. A Modified Single Metamaterial Split-Ring Resonator for Enhanced Sensitivity. Sensors. 2026;26(14):4659. doi:10.3390/s26144659

BibTeX
@article{Swileh2026,
  author = {Swileh, Amal and Saad, Rola and Khamas, Salam K},
  title = {A Modified Single Metamaterial Split-Ring Resonator for Enhanced Sensitivity},
  journal = {Sensors},
  year = {2026},
  volume = {26},
  number = {14},
  pages = {4659},
  doi = {10.3390/s26144659}
}