EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Fixed-Position Quasi-Static Load Calibration and Identification of an Aluminum Wing-Box Test Section Using Surface-Bonded Fiber Bragg Grating Sensors

Zhe Fan, Rui Bao, Junkai Sun, Hao Song

Sensors · 22.07.2026 · 26 (14) · 4650

DOI: 10.3390/s26144650 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 22.07.2026. Verfasst von Zhe Fan und 3 weiteren Autor:innen. Beteiligte Einrichtung: National Key Laboratory of Strength and Structural Integrity, Institute of Solid Mechanics, School of Aeronautic Science and Engineering, Beihang Uni…. Die Arbeit nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Section-load calibration is used in aircraft wing-box testing. This study evaluates a fixed-position quasi-static load-calibration and identification procedure for one 7050 aluminum wing-box test section instrumented with surface-bonded fiber Bragg grating (FBG) sensors. A multi-point FBG network was arranged on the skins and webs using finite-element-guided sensor placement to construct bending-, shear-, and torsion-related response features; strain-free reference FBGs provided temperature compensation. All experiments used the same specimen geometry, fixed-root boundary condition, sensor layout, and four actuator positions. Conditions 1–6 were used for regression calibration, whereas Conditions 7 and 8 were held out for interpolation-type validation within the same loading configuration. The maximum/average relative errors were 6.53%/1.51% for bending moment, 2.62%/0.86% for shear force, and 4.04%/1.23% for torsional moment. These results apply only to local laboratory calibration of the tested configuration and do not establish transfer to other geometries, boundary conditions, sensor layouts, loading positions, environmental conditions, or dynamic loading.

Schlagwörter

Stichwörter der Autor:innen

aircraft wing-box sectionfiber Bragg grating sensorquasi-static load calibrationstructural health monitoringtemperature compensation

Autor:innen und Institutionen

  • National Key Laboratory of Strength and Structural Integrity, Institute of Solid Mechanics, School of Aeronautic Science and Engineering, Beihang University, Beijing 100191, China.
  • AVIC Changcheng Institute of Metrology & Measurement, Beijing 100095, China.

Zitieren

APA

Fan, Z., Bao, R., Sun, J., & Song, H. (2026). Fixed-Position Quasi-Static Load Calibration and Identification of an Aluminum Wing-Box Test Section Using Surface-Bonded Fiber Bragg Grating Sensors. Sensors, 26(14), 4650. https://doi.org/10.3390/s26144650

Vancouver

Fan Z, Bao R, Sun J, Song H. Fixed-Position Quasi-Static Load Calibration and Identification of an Aluminum Wing-Box Test Section Using Surface-Bonded Fiber Bragg Grating Sensors. Sensors. 2026;26(14):4650. doi:10.3390/s26144650

BibTeX
@article{Fan2026,
  author = {Fan, Zhe and Bao, Rui and Sun, Junkai and Song, Hao},
  title = {Fixed-Position Quasi-Static Load Calibration and Identification of an Aluminum Wing-Box Test Section Using Surface-Bonded Fiber Bragg Grating Sensors},
  journal = {Sensors},
  year = {2026},
  volume = {26},
  number = {14},
  pages = {4650},
  doi = {10.3390/s26144650}
}
Kostenlos starten →