Sensor-Based Assessment of Quadriceps EMG-Amplitude-to-Torque Ratios at Different Knee Angles: An Exploratory Cross-Sectional Study
Sensors · 18.07.2026 · 26 (14) · 4568
DOI: 10.3390/s26144568 ↗Kurz gefasst
Querschnittstudie in der Zeitschrift Sensors, online erschienen am 18.07.2026. Verfasst von Zhaoxiang Zhang und 6 weiteren Autor:innen. Beteiligte Einrichtung: Doctoral School, Gdansk University of Physical Education and Sport, Kazimierza Górskiego Street 1, 80-336 Gdansk, Poland. Hauptthemen laut MEDLINE: Electromyography, Quadriceps Muscle, Knee Joint, Knee. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Surface electromyography (sEMG) normalized to mechanical output can describe electrical activation amplitude relative to torque, but such ratios should not be interpreted automatically as neuromuscular efficiency. This exploratory cross-sectional study compared quadriceps activation-to-torque ratios at 45° and 75° knee flexion and examined hypothesis-generating associations with countermovement jump (CMJ) outcomes. Seventeen participants performed two brief unilateral maximal isometric knee-extension trials at each angle. Wireless sEMG from the vastus lateralis (VL), vastus medialis (VM), and rectus femoris (RF) and Biodex torque were acquired separately and manually matched by participant, knee angle, and test set. Ratios were calculated as Noraxon-exported mean EMG amplitude divided by Biodex average peak torque. Ratios were higher at 45° than at 75° for VL (mean difference = 0.74 μV/(N·m), BCa 95% CI: 0.34–1.34; Holm-adjusted p = 0.020), VM (0.52, 0.09–0.72; p = 0.009), and RF (0.69, 0.22–1.32; p = 0.028). Exploratory Spearman correlations with CMJ outcomes ranged from −0.38 to 0.32 and were nonsignificant after false-discovery-rate correction. The findings indicate protocol-specific, angle-dependent differences, whereas CMJ associations remain inconclusive and require larger, reliability-focused studies with synchronized acquisition and fully documented signal processing.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Doctoral School, Gdansk University of Physical Education and Sport, Kazimierza Górskiego Street 1, 80-336 Gdansk, Poland.
- Department of Biomechanics and Sport Engineering, Gdansk University of Physical Education and Sport, Kazimierza Górskiego Street 1, 80-336 Gdansk, Poland.
- Faculty of Medicine, Wrocław University of Science and Technology, 50-370 Wrocław, Poland.
ORCID-Profile: Zhaoxiang Zhang, Małgorzata Tomicka, Xiaodan Guo, Mingmao Li, Marcin Krawczynski, Piotr Aschenbrenner, Adam Kawczyński
Zitieren
APA
Zhang, Z., Tomicka, M., Guo, X., Li, M., Krawczynski, M., Aschenbrenner, P., & Kawczyński, A. (2026). Sensor-Based Assessment of Quadriceps EMG-Amplitude-to-Torque Ratios at Different Knee Angles: An Exploratory Cross-Sectional Study. Sensors, 26(14), 4568. https://doi.org/10.3390/s26144568
Vancouver
Zhang Z, Tomicka M, Guo X, Li M, Krawczynski M, Aschenbrenner P, et al. Sensor-Based Assessment of Quadriceps EMG-Amplitude-to-Torque Ratios at Different Knee Angles: An Exploratory Cross-Sectional Study. Sensors. 2026;26(14):4568. doi:10.3390/s26144568
BibTeX
@article{Zhang2026,
author = {Zhang, Zhaoxiang and Tomicka, Małgorzata and Guo, Xiaodan and Li, Mingmao and Krawczynski, Marcin and Aschenbrenner, Piotr and Kawczyński, Adam},
title = {Sensor-Based Assessment of Quadriceps EMG-Amplitude-to-Torque Ratios at Different Knee Angles: An Exploratory Cross-Sectional Study},
journal = {Sensors},
year = {2026},
volume = {26},
number = {14},
pages = {4568},
doi = {10.3390/s26144568}
}
EUVIMED