EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Design and Testing of a Wearable Lower-Limb Exoskeleton for Investigating Falls Prevention

Bethany Gray, Erfan Shahabpoor iD, Andrew Plummer iD

Sensors · 17.07.2026 · 26 (14) · 4534

DOI: 10.3390/s26144534 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 17.07.2026. Verfasst von Bethany Gray und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Architecture and Civil Engineering, University of Bath, Bath BA2 7AY, UK. Hauptthemen laut MEDLINE: Accidental Falls, Exoskeleton Device, Wearable Electronic Devices, Robotics. Die Arbeit nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: University of Bath, Maxon young engineers program.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Wearable robots that can support balance and prevent falls hold great promise to increase the longevity and quality of life of the older population. However, a lack of understanding of human–robot dynamic interactions and users’ reactions to robot interventions can limit the functionality and usability of these robots. A wearable lower-limb robot was developed to study different strategies to proactively prevent falls during obstacle navigation and to investigate human–robot interactions and users’ reactions to different intervention parameters. A novel non-anthropomorphic architecture was designed for robot legs to allow the direct modulation of foot-placement position in the sagittal plane, using only a single active degree of freedom per leg. Three participants completed a series of walking trials wearing the robot, with different levels of robot intervention. The developed robot was able to successfully modify users’ stride length (e.g., 6–12% and 7.5–20% change in step length for 12 Nm robot hip flexion and extension torques, respectively) in the desired direction, indicating the possibility for assisted balance during obstacle navigation through foot-placement modulation. The measurements show that users’ reactions to the robot intervention is subject-specific and time-varying but, in all cases, plays a considerable role in the final movement trajectory. Controllers of the balance assistance robots must take into account the user’s personalized response to different intervention parameters, to improve functionality, efficiency and user comfort.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Accidental FallsExoskeleton DeviceWearable Electronic DevicesRoboticsLower ExtremityHumansEquipment DesignWalkingMaleFemale

Stichwörter der Autor:innen

balancefoot placementhuman–robot interactionnon-anthropomorphicpartial compensationstep-length modulationunder-actuated

Autor:innen und Institutionen

  • Department of Architecture and Civil Engineering, University of Bath, Bath BA2 7AY, UK.
  • Department of Mechanical Engineering, University of Bath, Bath BA2 7AY, UK.

ORCID-Profile: Erfan Shahabpoor, Andrew Plummer

Förderung

  • University of Bath
  • Maxon young engineers program

Zitieren

APA

Gray, B., Shahabpoor, E., & Plummer, A. (2026). Design and Testing of a Wearable Lower-Limb Exoskeleton for Investigating Falls Prevention. Sensors, 26(14), 4534. https://doi.org/10.3390/s26144534

Vancouver

Gray B, Shahabpoor E, Plummer A. Design and Testing of a Wearable Lower-Limb Exoskeleton for Investigating Falls Prevention. Sensors. 2026;26(14):4534. doi:10.3390/s26144534

BibTeX
@article{Gray2026,
  author = {Gray, Bethany and Shahabpoor, Erfan and Plummer, Andrew},
  title = {Design and Testing of a Wearable Lower-Limb Exoskeleton for Investigating Falls Prevention},
  journal = {Sensors},
  year = {2026},
  volume = {26},
  number = {14},
  pages = {4534},
  doi = {10.3390/s26144534}
}
Kostenlos starten →