Mechanical Testing of Metal-Packaged FBG-Based Sensors Before and After High-Fluence Reactor Irradiation

Yerzhan Sapatayev, Kuanysh Samarkhanov iD, Pavel Kashaykin iD, Almas Azimkhanov, Sergei Vasiliev iD, Alexander Tomashuk, Yersin Aryngazy, Vadim Bochkov, Kamilla Ilyasheva

Sensors · 08.07.2026 · 26 (14) · 4328

DOI: 10.3390/s26144328 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 08.07.2026. Verfasst von Yerzhan Sapatayev und 8 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Atomic Energy Branch of the National Nuclear Center of the Republic of Kazakhstan, 180010 Kurchatov, Kazakhstan. Die Arbeit nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Committee of Science of the Ministry of Science and Higher Education of the Republic of Kazakhstan.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Fiber Bragg grating (FBG)-based sensors are increasingly used for temperature and strain monitoring in both fission and fusion facilities, whereas their long-term mechanical reliability under intense γ–neutron fields remains insufficiently understood. Although radiation-resistant FBGs and optical fibers have demonstrated tolerance to fast-neutron fluences approaching 1020 n/cm2, the post-irradiation behavior of complete sensor assemblies, including their metallic packaging and joining regions, has received much less attention. This work presents methodology and results of assessing the post-irradiation mechanical properties of packaged FBG-based temperature and strain sensors. The investigated sensors were based on Cu-coated FBGs embedded in 316L stainless-steel bodies and joined using STEMET-1101 brazing filler metal. The sensors were irradiated in the cores of the IVG.1M and WWR-K research reactors to fast-neutron fluences of 4.5 × 1017 and 1.8 × 1020 n/cm2, with absorbed γ-doses of 29.1 MGy and 2.3 GGy, respectively. After decay storage and hot-cell disassembly, tensile testing, microhardness measurements, and SEM–EDS analysis were performed. The results demonstrate that the investigated metal-packaged FBG sensor of this design retained mechanical integrity under high-fluence reactor irradiation.

Schlagwörter

Stichwörter der Autor:innen

FBG-based sensorsSTEMET-1101 brazing filler metalmixed gamma-neutron irradiationpost-irradiation mechanical testing

Autor:innen und Institutionen

  • Institute of Atomic Energy Branch of the National Nuclear Center of the Republic of Kazakhstan, 180010 Kurchatov, Kazakhstan.
  • ITER Organization, 13115 St Paul Les Durance, France.
  • Prokhorov General Physics Institute of the Russian Academy of Sciences, Dianov Fiber Optics Research Centre, 119991 Moscow, Russia.
  • School of Sciences and Humanities, Nazarbayev University, 010000 Astana, Kazakhstan.

ORCID-Profile: Kuanysh Samarkhanov, Pavel Kashaykin, Sergei Vasiliev

Förderung

  • Committee of Science of the Ministry of Science and Higher Education of the Republic of Kazakhstan

Zitieren

APA

Sapatayev, Y., Samarkhanov, K., Kashaykin, P., Azimkhanov, A., Vasiliev, S., Tomashuk, A., Aryngazy, Y., Bochkov, V., & Ilyasheva, K. (2026). Mechanical Testing of Metal-Packaged FBG-Based Sensors Before and After High-Fluence Reactor Irradiation. Sensors, 26(14), 4328. https://doi.org/10.3390/s26144328

Vancouver

Sapatayev Y, Samarkhanov K, Kashaykin P, Azimkhanov A, Vasiliev S, Tomashuk A, et al. Mechanical Testing of Metal-Packaged FBG-Based Sensors Before and After High-Fluence Reactor Irradiation. Sensors. 2026;26(14):4328. doi:10.3390/s26144328

BibTeX
@article{Sapatayev2026,
  author = {Sapatayev, Yerzhan and Samarkhanov, Kuanysh and Kashaykin, Pavel and Azimkhanov, Almas and Vasiliev, Sergei and Tomashuk, Alexander and Aryngazy, Yersin and Bochkov, Vadim and Ilyasheva, Kamilla},
  title = {Mechanical Testing of Metal-Packaged FBG-Based Sensors Before and After High-Fluence Reactor Irradiation},
  journal = {Sensors},
  year = {2026},
  volume = {26},
  number = {14},
  pages = {4328},
  doi = {10.3390/s26144328}
}
Kostenlos starten →