Preliminary Field Evaluation of a Low-Cost IoT Workflow for Dissolved Oxygen Monitoring and Short-Horizon Forecasting in Nile Tilapia Aquaculture
Sensors · 04.07.2026 · 26 (13) · 4242
DOI: 10.3390/s26134242 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 04.07.2026. Verfasst von Ahmed Mohammed Al-Khaldi und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electrical and Communication Engineering, College of Engineering, National University of Science and Technology, P.O. Box 2322, Seeb 11…. Hauptthemen laut MEDLINE: Oxygen, Aquaculture, Environmental Monitoring, Cichlids. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Research and Innovation Authority (RIA), Oman, National University of Science and Technology, Muscat, Oman.
Abstract (Originalsprache)
Short-term fluctuations in dissolved oxygen are difficult to capture in warm outdoor Nile tilapia (Oreochromis niloticus) ponds using periodic manual measurements, yet they strongly influence fish performance and farm management. This study presents a preliminary field evaluation of a low-cost IoT workflow for dissolved oxygen monitoring and short-horizon forecasting in pond-based tilapia culture. An ESP32-based sensing node continuously measured dissolved oxygen, temperature, and pH, transmitted readings to a cloud backend, and generated short-horizon forecasts from 5 min aggregated windows. During live validation from 1 to 10 April 2026, the 30 min forecast achieved a mean absolute error of 0.783 mg/L and directional accuracy of 60.23%, with only modest improvement over a persistence baseline. The 6 h forecast achieved 1.109 mg/L and 53.82%, respectively, indicating limited predictive value at the extended horizon. An extended 47-day field deployment (May–June 2026) captured four sensor-recorded low-DO events and two documented power outages, causing sensor downtime and providing additional field-deployment evidence. These results demonstrate the engineering feasibility of the integrated workflow, but they do not establish robust operational forecasting validity because the data were collected from one pond, high-frequency records were temporally correlated, and independent reference-meter validation was not available. The study is, therefore, best interpreted as a proof-of-concept field evaluation that identifies practical requirements for future low-cost aquaculture forecasting systems.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Electrical and Communication Engineering, College of Engineering, National University of Science and Technology, P.O. Box 2322, Seeb 111, Oman.
ORCID-Profile: Ahmed Mohammed Al-Khaldi, Ragavesh Dhandapani, Mohammed Ahmed Al-Badri
Förderung
- Research and Innovation Authority (RIA), Oman
- National University of Science and Technology, Muscat, Oman
Zitieren
APA
Al-Khaldi, A. M., Dhandapani, R., & Al-Badri, M. A. (2026). Preliminary Field Evaluation of a Low-Cost IoT Workflow for Dissolved Oxygen Monitoring and Short-Horizon Forecasting in Nile Tilapia Aquaculture. Sensors, 26(13), 4242. https://doi.org/10.3390/s26134242
Vancouver
Al-Khaldi AM, Dhandapani R, Al-Badri MA. Preliminary Field Evaluation of a Low-Cost IoT Workflow for Dissolved Oxygen Monitoring and Short-Horizon Forecasting in Nile Tilapia Aquaculture. Sensors. 2026;26(13):4242. doi:10.3390/s26134242
BibTeX
@article{AlKhaldi2026,
author = {Al-Khaldi, Ahmed Mohammed and Dhandapani, Ragavesh and Al-Badri, Mohammed Ahmed},
title = {Preliminary Field Evaluation of a Low-Cost IoT Workflow for Dissolved Oxygen Monitoring and Short-Horizon Forecasting in Nile Tilapia Aquaculture},
journal = {Sensors},
year = {2026},
volume = {26},
number = {13},
pages = {4242},
doi = {10.3390/s26134242}
}
EUVIMED