EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Variable Impedance Control for Force Tracking in Multi-Mode Robotic Back Massage

Jingbo Xu iD, Chong Ren, Xiangjie Kong, Silu Chen iD

Sensors · 29.06.2026 · 26 (13) · 4115

DOI: 10.3390/s26134115 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 29.06.2026. Verfasst von Jingbo Xu und 3 weiteren Autor:innen. Beteiligte Einrichtung: School of Medical Devices, Zhejiang Pharmaceutical University, Ningbo 315500, China. Hauptthemen laut MEDLINE: Robotics, Massage. Die Arbeit nennt 54 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Hangzhou Science and Technology Commission, Zhejiang Provincial Natural Science Foundation, Hangzhou Municipal Key R&D Project.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Achieving safe physical interaction on the human back is challenging due to respiratory rhythms, complex topography, and varying tissue stiffness. To enable compliant force tracking within commercial closed position-control robot architectures, this paper presents an adaptive variable damping admittance control framework driven by multi-dimensional force sensor feedback. A stiffness-free admittance model is constructed to eliminate steady-state tracking errors, integrated with a nonlinear adaptive damping law that sensitively responds to real-time force sensor measurements. This mechanism rapidly dissipates dynamic impact energy during contacts while maintaining low impedance during steady state. Validated via a high-fidelity MATLAB R2024b-CoppeliaSim co-simulation platform replicating Traditional Chinese Medicine (TCM) manipulations, the proposed sensor-driven strategy significantly improves force tracking fidelity over traditional fixed-parameter control. Quantitative results demonstrate that across all complex therapeutic waveforms, the root mean square error (RMSE) remains below 0.42 N, the mean absolute error (MAE) is within 0.32 N, and the squared correlation coefficient (r2) exceeds 0.97. These findings confirm the high efficiency and clinical potential of the proposed framework.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

RoboticsMassageHumansElectric ImpedanceMedicine, Chinese Traditional

Stichwörter der Autor:innen

Traditional Chinese Medicineadmittance controlclosed architectureforce controlrobotic massagevariable impedance control

Autor:innen und Institutionen

  • School of Medical Devices, Zhejiang Pharmaceutical University, Ningbo 315500, China.
  • Ningbo Institute of Materials Technology and Engineering, Chinese Academy of Sciences, Ningbo 315201, China.

ORCID-Profile: Jingbo Xu, Silu Chen

Förderung

  • Hangzhou Science and Technology Commission
  • Zhejiang Provincial Natural Science Foundation
  • Hangzhou Municipal Key R&D Project
  • Zhejiang Department of Education
  • Ningbo Science and Technology Bureau
  • Zhejiang Natural Sciences Foundation

Zitieren

APA

Xu, J., Ren, C., Kong, X., & Chen, S. (2026). Variable Impedance Control for Force Tracking in Multi-Mode Robotic Back Massage. Sensors, 26(13), 4115. https://doi.org/10.3390/s26134115

Vancouver

Xu J, Ren C, Kong X, Chen S. Variable Impedance Control for Force Tracking in Multi-Mode Robotic Back Massage. Sensors. 2026;26(13):4115. doi:10.3390/s26134115

BibTeX
@article{Xu2026,
  author = {Xu, Jingbo and Ren, Chong and Kong, Xiangjie and Chen, Silu},
  title = {Variable Impedance Control for Force Tracking in Multi-Mode Robotic Back Massage},
  journal = {Sensors},
  year = {2026},
  volume = {26},
  number = {13},
  pages = {4115},
  doi = {10.3390/s26134115}
}
Kostenlos starten →