Characterization of Ultrasound Probe-Dependent Interference in Electromagnetic Tracking for Image-Guided Procedures
Sensors · 27.06.2026 · 26 (13) · 4096
DOI: 10.3390/s26134096 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 27.06.2026. Verfasst von Simão Valente und 5 weiteren Autor:innen. Beteiligte Einrichtung: 2Ai-Applied Artificial Intelligence Laboratory, School of Technology, Polytechnic University of Cávado and Ave (IPCA), 4750-810 Barcelos, Portugal. Hauptthemen laut MEDLINE: Surgery, Computer-Assisted, Electromagnetic Phenomena. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Fundação para a Ciência e Tecnologia, Foundation for Science and Technology, Karl Storz (Germany).
Abstract (Originalsprache)
Ultrasound (US) imaging is widely used to guide minimally invasive procedures such as percutaneous nephrolithotomy (PCNL), while electromagnetic (EM) tracking can complement US guidance by providing line-of-sight-independent instrument localization. However, US probes may distort the EM tracking field in a probe-dependent manner. This study characterized probe-induced EM interference for a conventional 3D/4D phased-array probe and a handheld wireless probe. Three experiments were conducted using an EM tracking system: spatial mapping of interference along each probe body, assessment of probe–sensor separation for the handheld probe, and evaluation of probe-induced tracking deviations in a simulated EM-guided PCNL setup with tracked needle and catheter sensors. EM-US calibration was then performed using low-interference sensor positions. The phased-array probe produced minimal disturbance, maintaining submillimetric positional and subdegree orientational precision across tested modes. Compared with the evaluated phased-array probe, the evaluated handheld wireless probe generated stronger, spatially localized interference, requiring ≥75 mm positional and ≥50 mm orientational separation to recover baseline precision. In the PCNL simulation, the phased-array probe maintained tracking stability, whereas the handheld probe introduced localized deviations. Both probes produced RMS calibration residuals below 1 mm under controlled conditions. These results provide device-specific baseline measurements and a workflow for probe-dependent interference assessment and sensor-placement optimization in EM-US navigation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- 2Ai-Applied Artificial Intelligence Laboratory, School of Technology, Polytechnic University of Cávado and Ave (IPCA), 4750-810 Barcelos, Portugal.
- Life and Health Sciences Research Institute (ICVS), School of Medicine, University of Minho, 4710-057 Braga, Portugal.
- ICVS/3B's-PT Government Associate Laboratory, 4710-057 Braga/Guimarães, Portugal.
- LASI Intelligent Systems Associate Laboratory, 4800-058 Guimarães, Portugal.
- Karl Storz SE & Co. KG, 78532 Tuttlingen, Germany.
- Faculty of Medicine, University of Lisbon, 1649-028 Lisbon, Portugal.
ORCID-Profile: Simão Valente, Pedro Morais, Estêvão Lima, João L Vilaça
Förderung
- Fundação para a Ciência e Tecnologia
- Foundation for Science and Technology
- Karl Storz (Germany)
- Health Cluster Portugal
- KARL STORZ SE & Co. KG
- Innovation Pact HfPT—Health from Portugal
Zitieren
APA
Valente, S., Morais, P., Fritz, A., Stern, A., Lima, E., & Vilaça, J. L. (2026). Characterization of Ultrasound Probe-Dependent Interference in Electromagnetic Tracking for Image-Guided Procedures. Sensors, 26(13), 4096. https://doi.org/10.3390/s26134096
Vancouver
Valente S, Morais P, Fritz A, Stern A, Lima E, Vilaça JL. Characterization of Ultrasound Probe-Dependent Interference in Electromagnetic Tracking for Image-Guided Procedures. Sensors. 2026;26(13):4096. doi:10.3390/s26134096
BibTeX
@article{Valente2026,
author = {Valente, Simão and Morais, Pedro and Fritz, Andreas and Stern, Antonia and Lima, Estêvão and Vilaça, João L},
title = {Characterization of Ultrasound Probe-Dependent Interference in Electromagnetic Tracking for Image-Guided Procedures},
journal = {Sensors},
year = {2026},
volume = {26},
number = {13},
pages = {4096},
doi = {10.3390/s26134096}
}
EUVIMED