EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Comparative Analysis of Tri-Polar Concentric Ring and Conventional Electrodes for Overt and Covert Speech

Paras Qadir Memon iD, Chuck Anderson iD, Zeeshan Qadir Memon iD, Shoaib Memon iD, Adnan Qadir

Sensors · 27.06.2026 · 26 (13) · 4084

DOI: 10.3390/s26134084 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Sensors, online erschienen am 27.06.2026. Verfasst von Paras Qadir Memon und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Computer Science, Colorado State University, Fort Collins, CO 80523, USA. Hauptthemen laut MEDLINE: Electroencephalography, Speech. Die Arbeit nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NINDS NIH HHS, NIH, Fulbright Program.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The Brain–Computer Interface (BCI) is a system that enables communication between the brain and external devices by translating brain activity into commands. Electroencephalography (EEG) is a commonly used modality for measuring brain activity. However, its low signal-to-noise ratio (SNR) and electrode reference problems lead to poor spatial resolution. As a result, EEG signals are often contaminated with physiological artifacts such as muscle movements. Therefore, this study used novel tripolar concentric ring electrodes (TCREs) to record brain signals related to overt and covert speech. Brain signals associated with overt and covert speech were recorded using TCRE and disc electrodes. Classification algorithms, including K-Nearest Neighbors (KNN), Fully Connected Neural Networks (FCNN), and Convolutional Neural Networks (CNN), were used to classify the TCRE and conventional EEG signals. The data were collected from 16 healthy participants, consisting of 10 males and 6 females. The experimental results demonstrate that TCREs provide superior performance compared to conventional disc electrodes. In addition, the 0.5–1.2s interval, corresponding to the peak stimulus window, exhibits a maximum power of 250μV. The average accuracy achieved during this peak epoch was 86.25%, whereas the remaining epoch shows an accuracy of 83.5% using TCREs.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ElectroencephalographySpeechHumansElectrodesFemaleBrain-Computer InterfacesMaleConvolutional Neural NetworksAlgorithmsSignal Processing, Computer-AssistedSignal-To-Noise RatioBrainAdult

Stichwörter der Autor:innen

Biosensorsbiomedical signal analysisbrain–computer interface (BCI)concentric ring electrodesdeep learningelectroencephalography (EEG)machine learningneural signal classificationovert and covert speechsurface Laplacian

Autor:innen und Institutionen

  • Department of Computer Science, Colorado State University, Fort Collins, CO 80523, USA.
  • Oregon State University, Corvallis, OR 97331, USA.
  • University of Arkansas at Little Rock, Little Rock, AR 72204, USA.
  • Aga Khan University, Karachi 74800, Pakistan.

ORCID-Profile: Paras Qadir Memon, Chuck Anderson, Zeeshan Qadir Memon, Shoaib Memon

Förderung

  • NINDS NIH HHS
  • NIH
  • Fulbright Program

Zitieren

APA

Memon, P. Q., Anderson, C., Memon, Z. Q., Memon, S., & Qadir, A. (2026). Comparative Analysis of Tri-Polar Concentric Ring and Conventional Electrodes for Overt and Covert Speech. Sensors, 26(13), 4084. https://doi.org/10.3390/s26134084

Vancouver

Memon PQ, Anderson C, Memon ZQ, Memon S, Qadir A. Comparative Analysis of Tri-Polar Concentric Ring and Conventional Electrodes for Overt and Covert Speech. Sensors. 2026;26(13):4084. doi:10.3390/s26134084

BibTeX
@article{Memon2026,
  author = {Memon, Paras Qadir and Anderson, Chuck and Memon, Zeeshan Qadir and Memon, Shoaib and Qadir, Adnan},
  title = {Comparative Analysis of Tri-Polar Concentric Ring and Conventional Electrodes for Overt and Covert Speech},
  journal = {Sensors},
  year = {2026},
  volume = {26},
  number = {13},
  pages = {4084},
  doi = {10.3390/s26134084}
}
Kostenlos starten →