Indirect Estimation of Absorbed Infrared LED Radiant Power Using Contactless Thermal Sensing
Sensors · 26.06.2026 · 26 (13) · 4055
DOI: 10.3390/s26134055 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 26.06.2026. Verfasst von Sorin Eugen Popa und 4 weiteren Autor:innen. Beteiligte Einrichtung: The Department of Power Engineering and Computer Science, Faculty of Engineering, "Vasile Alecsandri" University of Bacau, 600115 Bacau, Romania. Die Arbeit nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
The accurate characterization of low-power near-infrared LEDs typically requires costly radiometric equipment, limiting broader accessibility. This study proposes a low-cost indirect method for comparative NIR LED characterization based on the thermal response of black-coated aluminum absorbing targets monitored by a commercial MLX90614 contactless temperature sensor integrated with an ESP32 acquisition system. The absorbed optical power was estimated from a steady-state energy-balance model combining convective and radiative heat transfer, with geometry-dependent effective coefficients derived for 10 mm and 15 mm diameter targets. Experiments were conducted using 850 nm and 940 nm LEDs at drive currents between 30 mA and 100 mA. The absorbed power increased linearly with the drive current and electrical input power across all configurations, with R2 values of 0.995–0.997 and 0.996–0.999, respectively. The 15 mm targets exhibited higher capture ratios (10.4–11.9%) compared to the 10 mm targets (8.4–9.4%). The combined measurement uncertainty ranged from 13% at high drive currents to nearly 70% at low drive currents, with the temperature-rise sensitivity being the dominant factor; within the recommended operating range (≥70 mA for 10 mm and ≥80 mA for 15 mm targets), the uncertainty remained below 25%. The proposed platform enables reliable comparative characterization of low-power NIR emitters using exclusively off-the-shelf components.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- The Department of Power Engineering and Computer Science, Faculty of Engineering, "Vasile Alecsandri" University of Bacau, 600115 Bacau, Romania.
ORCID-Profile: Sorin Eugen Popa, Roxana Margareta Grigore
Zitieren
APA
Popa, S. E., Puiu, P. G., Andrioaia, D. A., Grigore, R. M., & Avădanei, R. L. (2026). Indirect Estimation of Absorbed Infrared LED Radiant Power Using Contactless Thermal Sensing. Sensors, 26(13), 4055. https://doi.org/10.3390/s26134055
Vancouver
Popa SE, Puiu PG, Andrioaia DA, Grigore RM, Avădanei RL. Indirect Estimation of Absorbed Infrared LED Radiant Power Using Contactless Thermal Sensing. Sensors. 2026;26(13):4055. doi:10.3390/s26134055
BibTeX
@article{Popa2026,
author = {Popa, Sorin Eugen and Puiu, Petru Gabriel and Andrioaia, Dragoș Alexandru and Grigore, Roxana Margareta and Avădanei, Ramona Lenuța},
title = {Indirect Estimation of Absorbed Infrared LED Radiant Power Using Contactless Thermal Sensing},
journal = {Sensors},
year = {2026},
volume = {26},
number = {13},
pages = {4055},
doi = {10.3390/s26134055}
}
EUVIMED