NeuroStat: An Open-Source EEG Connectivity Platform for Randomised Controlled Trials
Sensors · 24.06.2026 · 26 (13) · 4019
DOI: 10.3390/s26134019 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 24.06.2026. Verfasst von Usman Ghani und 4 weiteren Autor:innen. Beteiligte Einrichtung: Centre for Chiropractic Research, New Zealand College of Chiropractic, Auckland 1060, New Zealand. Hauptthemen laut MEDLINE: Electroencephalography, Randomized Controlled Trials as Topic. Die Arbeit nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: King Abdulaziz University, Deanship of Scientific Research (DSR) at King Abdulaziz University, Jeddah, Saudi Arabia.
Abstract (Originalsprache)
Background
Electroencephalographic (EEG) functional connectivity analysis requires multiple signal-processing, source-modelling, and statistical steps that can limit its adoption in clinician-led randomised controlled trials (RCTs). NeuroStat was developed as a prototype research tool to integrate this workflow; formal usability validation with clinician end-users has not yet been conducted.
Methods
NeuroStat is an open-source Python/PyQt6 desktop application that integrates automated artefact removal (a Generalised Eigenvalue Decomposition for Artefact Identification [GEDAI] pathway and a traditional Artefact Subspace Reconstruction (ASR)/Independent Component Analysis (ICA)/ICLabel pathway), boundary element model (BEM) source localisation using the Desikan–Killiany atlas (68 cortical regions), Phase Lag Index (PLI) connectivity estimation across five canonical frequency bands, and RCT-oriented statistical analysis. Evaluation separated sensor-space and source-space claims: a sensor-level simulation (repeated across five independent random seeds) tested preprocessing robustness, a repeated source-space simulation tested recovery of a known cortical parcel-pair contrast after forward projection and inverse reconstruction, a PhysioNet benchmark tested posterior Desikan–Killiany alpha PLI in 20 healthy adults, and an illustrative application to 20 sessions from a published chiropractic RCT demonstrated real-world workflow applicability.
Results
In the sensor-level simulation benchmark, the Traditional pathway achieved a mean absolute error of 0.168 ± 0.017 PLI units and root mean squared error of 0.219 ± 0.045 (mean ± SD across five independent random seeds) across all artefact conditions. In the source-space simulation, reconstructed alpha PLI for the known bilateral lateral-occipital parcel pair exceeded anterior control edges across 60 repeated condition runs (mean known-control difference = 0.105 PLI units, 95% CI 0.096–0.114; t(59) = 22.61, p < 0.001). In the PhysioNet source-space benchmark, posterior Desikan–Killiany alpha PLI was higher during eyes-closed than eyes-open rest (Cohen’s d = 0.85, p = 0.001; 16/20 subjects showing the expected direction) after ICLabel-enabled preprocessing. In the pilot RCT application, all 20 sessions completed processing without manual intervention, with default-mode network alpha PLI showing a pre-to-post change of +0.071 in the intervention group versus +0.015 in the active control group.
Conclusions
NeuroStat integrates preprocessing, source-space construction, connectivity estimation, and statistical reporting within a parameter-logged desktop workflow for EEG functional connectivity studies. Current evidence supports initial technical feasibility, sensor-level preprocessing robustness for one pathway in controlled simulations, source-space recovery of a known parcel-level contrast, source-space sensitivity to an expected posterior alpha resting-state contrast, and error-free processing across 20 real RCT sessions in a pilot workflow demonstration. Formal usability testing, test–retest reliability analysis, participant-specific source-model validation, and clinical-population validation remain necessary before clinician-facing or trial-deployment claims can be made.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Centre for Chiropractic Research, New Zealand College of Chiropractic, Auckland 1060, New Zealand.
- Department of Information Technology, Faculty of Computing and Information Technology, King Abdulaziz University, Jeddah 21589, Saudi Arabia.
- School of Applied IT, Whitecliffe, Auckland 1010, New Zealand.
- Health and Rehabilitation Research Institute, Auckland University of Technology, Auckland 1010, New Zealand.
- Centre for Sensory-Motor Interaction, Department of Health Science and Technology, Aalborg University, 9220 Aalborg, Denmark.
ORCID-Profile: Usman Ghani, Iftikhar Ahmad, Shahbaz Pervez, Seyed Ebrahim Hosseini, Imran Khan Niazi
Förderung
- King Abdulaziz University
- Deanship of Scientific Research (DSR) at King Abdulaziz University, Jeddah, Saudi Arabia
Zitieren
APA
Ghani, U., Ahmad, I., Pervez, S., Hosseini, S. E., & Niazi, I. K. (2026). NeuroStat: An Open-Source EEG Connectivity Platform for Randomised Controlled Trials. Sensors, 26(13), 4019. https://doi.org/10.3390/s26134019
Vancouver
Ghani U, Ahmad I, Pervez S, Hosseini SE, Niazi IK. NeuroStat: An Open-Source EEG Connectivity Platform for Randomised Controlled Trials. Sensors. 2026;26(13):4019. doi:10.3390/s26134019
BibTeX
@article{Ghani2026,
author = {Ghani, Usman and Ahmad, Iftikhar and Pervez, Shahbaz and Hosseini, Seyed Ebrahim and Niazi, Imran Khan},
title = {NeuroStat: An Open-Source EEG Connectivity Platform for Randomised Controlled Trials},
journal = {Sensors},
year = {2026},
volume = {26},
number = {13},
pages = {4019},
doi = {10.3390/s26134019}
}
EUVIMED