Improving UV Stability of SiO2/SiNx-Passivated Silicon Photodiodes Through Shallow Junction Implantation and Oxide Regrowth
Sensors · 24.06.2026 · 26 (13) · 3991
DOI: 10.3390/s26133991 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 24.06.2026. Verfasst von Michael N Getz und 10 weiteren Autor:innen. Beteiligte Einrichtung: Smart Sensors and Microsystems, SINTEF Digital, 0314 Oslo, Norway. Die Arbeit nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: EURAMET - European Association of National Metrology Institutes, European Partnership on Metrology.
Abstract (Originalsprache)
Induced-junction silicon photodiodes based on SiO2/SiNx surface passivation are attractive for high-accuracy radiometry, but their use in the deep ultraviolet is limited by UV-induced degradation of the dielectric stack. In this work, we investigate the degradation of SiO2/SiNx-passivated p-type silicon photodiodes under UV irradiation and evaluate strategies for improving stability through shallow implanted junctions and oxide processing. Capacitance–voltage measurements on MIS capacitors and lifetime measurements on symmetrically passivated wafers show that UV exposure causes a rapid reduction in effective dielectric charge and carrier lifetime, followed by saturation at higher dose, consistent with filling of a finite population of electrically active trap states. Induced-junction photodiodes exhibit rapid photocurrent loss at 222 nm and, in some cases, eventual collapse, indicating that the remaining effective dielectric charge is insufficient to sustain the induced junction. To maintain junction functionality after UV exposure, shallow As- and Sb-implanted junctions are employed, resulting in an initial reduction during 222 nm exposure followed by stabilization at around 80–85% of the initial value up to the highest tested dose of 200 J/cm2. Further improvement is achieved by stripping and regrowing the implanted screen oxide before SiNx deposition, yielding nearly unchanged photocurrent after prolonged 222 nm exposure up to ca. 500 J/cm2. These results show that UV stability can be substantially improved by reducing device dependence on dielectric-induced inversion and by improving post-implantation interfacial oxide quality.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Smart Sensors and Microsystems, SINTEF Digital, 0314 Oslo, Norway.
- RISE Research Institutes of Sweden, 50115 Borås, Sweden.
- Department of Solar Energy Materials and Technology, Institute for Energy Technology, 2027 Kjeller, Norway.
- Physikalisch-Technische Bundesanstalt, 10587 Berlin, Germany.
- Metrology Research Institute, Aalto University, 02150 Espoo, Finland.
- The Norwegian Metrology Service (Justervesenet), 2027 Kjeller, Norway.
ORCID-Profile: Michael N Getz, Ozhan Koybasi, Fredrik Edhborg, Ørnulf Nordseth, Tobias Pohl, Marco Povoli, Stefan Källberg, Lutz Werner
Förderung
- EURAMET - European Association of National Metrology Institutes
- European Partnership on Metrology
Zitieren
APA
Getz, M. N., Koybasi, O., Edhborg, F., Nordseth, Ø., Hesse, S., Pohl, T., Povoli, M., Källberg, S., Werner, L., Ikonen, E., & Gran, J. (2026). Improving UV Stability of SiO2/SiNx-Passivated Silicon Photodiodes Through Shallow Junction Implantation and Oxide Regrowth. Sensors, 26(13), 3991. https://doi.org/10.3390/s26133991
Vancouver
Getz MN, Koybasi O, Edhborg F, Nordseth Ø, Hesse S, Pohl T, et al. Improving UV Stability of SiO2/SiNx-Passivated Silicon Photodiodes Through Shallow Junction Implantation and Oxide Regrowth. Sensors. 2026;26(13):3991. doi:10.3390/s26133991
BibTeX
@article{Getz2026,
author = {Getz, Michael N and Koybasi, Ozhan and Edhborg, Fredrik and Nordseth, Ørnulf and Hesse, Steven and Pohl, Tobias and Povoli, Marco and Källberg, Stefan and Werner, Lutz and Ikonen, Erkki and Gran, Jarle},
title = {Improving UV Stability of SiO2/SiNx-Passivated Silicon Photodiodes Through Shallow Junction Implantation and Oxide Regrowth},
journal = {Sensors},
year = {2026},
volume = {26},
number = {13},
pages = {3991},
doi = {10.3390/s26133991}
}
EUVIMED