EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Non-Contact Ultrasonic Assessment of Corrosion in Steel Specimens

Lukas Peterson, Andrei Zagrai iD, ThankGod Nwokocha, T David Burleigh iD

Sensors · 20.06.2026 · 26 (12) · 3923

DOI: 10.3390/s26123923 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 20.06.2026. Verfasst von Lukas Peterson und 3 weiteren Autor:innen. Beteiligte Einrichtung: Mechanical Engineering Department, New Mexico Institute of Mining and Technology, 801 Leroy Pl, Socorro, NM 87801, USA. Die Arbeit nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Nuclear Security Administration.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Ultrasonic thickness resonance can be effectively used to detect and quantify the level of corrosion in steel nuclear storage containers as well as other corrosion-prone thin-walled structures, such as pipes and storage tanks. Electro-Magnetic Acoustic Transducers (EMATs) have several advantages over more traditional piezoelectric-based transducers; namely, they can be used in a non-contact fashion on robotic platforms, allowing for measurements regardless of surface conditions or temperature. The major challenge of EMAT application is the power required to counteract the low actuation efficiency, which is achieved with a high-power ultrasonic pulse generator and a transformer circuit. Resonance techniques, in which most of the energy is concentrated near structural resonance frequencies, are preferable to improve efficiency of electro-magnetic acoustic measurements. This methodology was applied to 316L stainless steel thin plates subjected to uniform corrosion as well as pitting corrosion imitating different damage scenarios in a nuclear waste container. The resonant peak frequency shift was found to be proportional to the severity of corrosion for minimally corroded samples. However, the complete disappearance of the resonance peak was observed in the samples with severe corrosion damage. The EMAT liftoff distance was studied to quantify its effect on the amplitude, spread, and frequency of resonant peaks. Recommendations for use of EMATs for assessing corrosion damage are presented. The study demonstrates the success of frequency-based detection of corrosion damage in 316L stainless steel used in fabrication of nuclear waste storage containers.

Schlagwörter

Stichwörter der Autor:innen

EMATcorrosiondispersion curveliftoffresonancesteelthickness measurement

Autor:innen und Institutionen

  • Mechanical Engineering Department, New Mexico Institute of Mining and Technology, 801 Leroy Pl, Socorro, NM 87801, USA.
  • Materials & Metallurgical Engineering, New Mexico Institute of Mining and Technology, 801 Leroy Pl, Socorro, NM 87801, USA.

ORCID-Profile: Andrei Zagrai, T David Burleigh

Förderung

  • National Nuclear Security Administration

Zitieren

APA

Peterson, L., Zagrai, A., Nwokocha, T., & Burleigh, T. D. (2026). Non-Contact Ultrasonic Assessment of Corrosion in Steel Specimens. Sensors, 26(12), 3923. https://doi.org/10.3390/s26123923

Vancouver

Peterson L, Zagrai A, Nwokocha T, Burleigh TD. Non-Contact Ultrasonic Assessment of Corrosion in Steel Specimens. Sensors. 2026;26(12):3923. doi:10.3390/s26123923

BibTeX
@article{Peterson2026,
  author = {Peterson, Lukas and Zagrai, Andrei and Nwokocha, ThankGod and Burleigh, T David},
  title = {Non-Contact Ultrasonic Assessment of Corrosion in Steel Specimens},
  journal = {Sensors},
  year = {2026},
  volume = {26},
  number = {12},
  pages = {3923},
  doi = {10.3390/s26123923}
}