Single-Lead ECG Arrhythmia Classification Based on Peak-Enhanced Attention Network and Quality-Aware GAN Data Augmentation Framework
Sensors · 17.06.2026 · 26 (12) · 3852
DOI: 10.3390/s26123852 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 17.06.2026. Verfasst von Yaoyu Zhang und 1 weiteren Autor:innen. Beteiligte Einrichtung: The School of Electrical Engineering and Automation, Anhui University, Hefei 230601, China. Hauptthemen laut MEDLINE: Electrocardiography, Arrhythmias, Cardiac. Die Arbeit nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Anhui Provincial Natural Science Foundation,, Anhui Provincial Natural Science Foundation, China.
Abstract (Originalsprache)
Single-lead electrocardiogram (ECG) is widely used in wearable devices for atrial fibrillation (AF) screening. Nevertheless, subtle pathological characteristics like P-waves and f-waves in practical signals are vulnerable to noise contamination. Meanwhile, the scarcity of high-quality annotated abnormal data instances leads to severe class imbalance. To mitigate these issues, we present an end-to-end framework designed for arrhythmia diagnosis using single-lead ECG signals, which integrates quality-aware data augmentation with a Peak-Enhanced attention mechanism. First, to mitigate the problem of data imbalance, a Quality-Aware Generative Adversarial Network (QA-GAN) is designed. This network integrates a signal quality evaluation module based on signal kurtosis, together with a dynamic soft-label training scheme, guiding the generator to prioritize learning high-quality morphological features, thereby synthesizing high-fidelity minority class samples. Second, to accurately capture subtle pathological features in electrocardiograms, a Peak-Enhanced Attention Convolutional Network (PEAC-Net) classification model is proposed. This model incorporates a Peak-Enhanced Attention (PE-Att) module, which employs learnable derivative convolutional kernels to precisely identify the transition points in the ECG signal. Furthermore, by integrating one-dimensional multi-scale dilated convolution (DSGC1D) with bidirectional LSTM, the model achieves effective capturing of both fine-grained local morphological features and long-range global rhythm patterns. Experimental results on the PhysioNet 2017 dataset indicate that the presented model attains an accuracy of 0.902 and a macro-F1 score of 0.880, respectively, outperforming other state-of-the-art models and also exhibiting robust data adaptability on the MIT-BIH dataset.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- The School of Electrical Engineering and Automation, Anhui University, Hefei 230601, China.
Förderung
- Anhui Provincial Natural Science Foundation,
- Anhui Provincial Natural Science Foundation, China
Zitieren
APA
Zhang, Y., & Xia, Y. (2026). Single-Lead ECG Arrhythmia Classification Based on Peak-Enhanced Attention Network and Quality-Aware GAN Data Augmentation Framework. Sensors, 26(12), 3852. https://doi.org/10.3390/s26123852
Vancouver
Zhang Y, Xia Y. Single-Lead ECG Arrhythmia Classification Based on Peak-Enhanced Attention Network and Quality-Aware GAN Data Augmentation Framework. Sensors. 2026;26(12):3852. doi:10.3390/s26123852
BibTeX
@article{Zhang2026,
author = {Zhang, Yaoyu and Xia, Yi},
title = {Single-Lead ECG Arrhythmia Classification Based on Peak-Enhanced Attention Network and Quality-Aware GAN Data Augmentation Framework},
journal = {Sensors},
year = {2026},
volume = {26},
number = {12},
pages = {3852},
doi = {10.3390/s26123852}
}
EUVIMED