EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A Joint-Level Hybrid Framework for Gait Analysis Using Camera–IMU Fusion and LSTM-Based Temporal Correction

Eunju Ha, Jong-Wook Kim iD

Sensors · 16.06.2026 · 26 (12) · 3828

DOI: 10.3390/s26123828 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 16.06.2026. Verfasst von Eunju Ha und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electronic Engineering, Seunghak Campus, Dong-A University, Busan 49315, Republic of Korea. Hauptthemen laut MEDLINE: Gait Analysis, Gait. Die Arbeit nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministry of Trade, Industry and Energy.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Gait analysis is an essential tool in clinical domains for diagnosing musculoskeletal disorders and evaluating rehabilitation, yet traditional marker-based systems are limited by high costs and spatial constraints. To overcome these challenges, this study proposes and evaluates a joint-level hybrid framework that integrates a single RGB camera with two shoe-mounted inertial measurement units (IMUs) to leverage their complementary strengths. The camera-based module estimates hip and knee sagittal joint angles using 3D pose estimation, where the DEAS optimization algorithm aligns estimated coordinates with a humanoid model, and an LSTM-based refinement network corrects hip angles by referencing more accurately estimated knee data. Simultaneously, the IMU-based module estimates sagittal ankle angles through kinematic chain relationships that combine camera-derived proximal joint information with IMU-measured foot orientation. Experimental validation with 11 healthy participants in a controlled laboratory environment demonstrates promising estimation performance, achieving an average mean absolute error (MAE) of 7.89° and RMSE of 10.09° on the held-out test set across sagittal hip, knee, and ankle angles. Leave-one-subject-out (LOSO) cross-validation of the LSTM correction model further confirmed its generalizability, yielding an average MAE of 6.40° across bilateral hip angles. By accurately mitigating the trunk-inclination-induced overestimation of hip angles with a minimal sensor configuration (one camera and two IMUs), the proposed framework provides a practical and interpretable approach for portable lower limb gait analysis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Gait AnalysisGaitHumansAlgorithmsBiomechanical PhenomenaLong Short Term MemoryMotion CaptureKnee JointMaleFemaleHip JointAdultAnkle Joint

Stichwörter der Autor:innen

LSTMRGB cameragait analysisinertial measurement unitjoint angle estimationsensor fusion

Autor:innen und Institutionen

  • Department of Electronic Engineering, Seunghak Campus, Dong-A University, Busan 49315, Republic of Korea.

ORCID-Profile: Jong-Wook Kim

Förderung

  • Ministry of Trade, Industry and Energy

Zitieren

APA

Ha, E., & Kim, J. W. (2026). A Joint-Level Hybrid Framework for Gait Analysis Using Camera–IMU Fusion and LSTM-Based Temporal Correction. Sensors, 26(12), 3828. https://doi.org/10.3390/s26123828

Vancouver

Ha E, Kim JW. A Joint-Level Hybrid Framework for Gait Analysis Using Camera–IMU Fusion and LSTM-Based Temporal Correction. Sensors. 2026;26(12):3828. doi:10.3390/s26123828

BibTeX
@article{Ha2026,
  author = {Ha, Eunju and Kim, Jong-Wook},
  title = {A Joint-Level Hybrid Framework for Gait Analysis Using Camera–IMU Fusion and LSTM-Based Temporal Correction},
  journal = {Sensors},
  year = {2026},
  volume = {26},
  number = {12},
  pages = {3828},
  doi = {10.3390/s26123828}
}
Kostenlos starten →