EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Magnetic Anomaly Detection Based on a Multi-Parameter-Constrained Mirror Dual-Branch Biased Monostable Stochastic Resonance System

Rongxiang Xia, Mingxi Chen iD, Lizhi Hong, Zhiyuan Ai, Shaojie Ma

Sensors · 13.06.2026 · 26 (12) · 3776

DOI: 10.3390/s26123776 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 13.06.2026. Verfasst von Rongxiang Xia und 4 weiteren Autor:innen. Beteiligte Einrichtung: School of Mechanical Engineering, Nanjing University of Science and Technology, Nanjing 210094, China. Die Arbeit nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Magnetic anomaly detection is vulnerable to environmental noise and insufficient prior target information, making non-periodic anomaly signals difficult to detect at low-signal-to-noise-ratio (SNR) conditions. This paper proposes a detection method based on a multi-parameter-constrained mirror dual-branch biased monostable stochastic resonance (SR) system. Nonlinear odd-order bias terms are introduced into the conventional biased monostable potential function to build a multi-parameter-controllable SR model. This improves regulation of potential-well width, depth, and wall morphology, enhancing noise-energy utilization and responses to non-periodic features. Considering peak-type, valley-type, and bipolar anomaly morphologies, a mirror dual-branch SR structure is developed to cooperatively detect features with different polarities. To preserve temporal waveforms and time–frequency structures during parameter optimization, a composite metric combining the correlation coefficient and wavelet-domain image structural similarity index is constructed. Multi-fidelity robust Bayesian optimization is used to obtain a unified robust parameter set for the magnetic anomaly signal family. Experiments with simulated colored noise and measured geomagnetic noise show that the proposed method effectively recovers magnetic anomaly features under strong noise. At −19 dB SNR, its detection probability remains above 80%. Compared with orthogonal basis function decomposition, empirical mode decomposition, and complete ensemble empirical mode decomposition with adaptive noise, the method achieves better noise suppression, feature preservation, and detection performance under low-SNR conditions.

Schlagwörter

Stichwörter der Autor:innen

biased monostable systemmagnetic anomaly detectionmirror dual-branch structurerobust Bayesian optimizationstochastic resonance

Autor:innen und Institutionen

  • School of Mechanical Engineering, Nanjing University of Science and Technology, Nanjing 210094, China.

ORCID-Profile: Mingxi Chen

Zitieren

APA

Xia, R., Chen, M., Hong, L., Ai, Z., & Ma, S. (2026). Magnetic Anomaly Detection Based on a Multi-Parameter-Constrained Mirror Dual-Branch Biased Monostable Stochastic Resonance System. Sensors, 26(12), 3776. https://doi.org/10.3390/s26123776

Vancouver

Xia R, Chen M, Hong L, Ai Z, Ma S. Magnetic Anomaly Detection Based on a Multi-Parameter-Constrained Mirror Dual-Branch Biased Monostable Stochastic Resonance System. Sensors. 2026;26(12):3776. doi:10.3390/s26123776

BibTeX
@article{Xia2026,
  author = {Xia, Rongxiang and Chen, Mingxi and Hong, Lizhi and Ai, Zhiyuan and Ma, Shaojie},
  title = {Magnetic Anomaly Detection Based on a Multi-Parameter-Constrained Mirror Dual-Branch Biased Monostable Stochastic Resonance System},
  journal = {Sensors},
  year = {2026},
  volume = {26},
  number = {12},
  pages = {3776},
  doi = {10.3390/s26123776}
}