Non-Contact Blood Pressure Prediction Using Radar with a Lightweight Temporal Multi-Scale Feature Fusion Network
Sensors · 31.05.2026 · 26 (11) · 3468
DOI: 10.3390/s26113468 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 31.05.2026. Verfasst von Yuhan Liu und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of Optoelectronic Information and Computer Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China. Hauptthemen laut MEDLINE: Blood Pressure, Blood Pressure Determination, Radar. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Natural Science Foundation of Shanghai, Terahertz Precision Biomedical Technology Discipline Innovation and Intelligence Project.
Abstract (Originalsprache)
Hypertension is a major global health issue, and continuous, convenient blood pressure monitoring is of great significance for early screening and intervention. To address the insufficient exploitation of multi-scale temporal features and the high model complexity in existing radar-based non-contact blood pressure prediction methods, we propose a lightweight temporal multi-scale feature fusion network (LULMNet), for blood pressure prediction and waveform reconstruction. LULMNet adopts a two-stage training strategy. In the first stage, a lightweight one-dimensional U-Net (1D U-Net) is employed for blood pressure waveform reconstruction and intermediate-to-deep temporal feature extraction. In the second stage, systolic and diastolic blood pressure are estimated via multi-scale fusion of intermediate and deep features from the encoder of the 1D U-Net, followed by LSTM-based temporal modeling and regression through a global average pooling (GAP)and a two-layer fully connected prediction head. Experimental results show that the proposed model achieves an error of 3.21 ± 4.94 mmHg for systolic blood pressure (SBP) and 2.25 ± 3.39 mmHg for diastolic blood pressure (DBP), satisfying the Grade A standard of the British Hypertension Society (BHS). In addition, the normalized mean absolute error (NMAE) for waveform reconstruction is as low as 0.044. These results indicate that the proposed method maintains low model complexity while ensuring prediction accuracy, with only 3.0 M parameters and 0.37 G floating-point operations (FLOPs), demonstrating strong potential for non-contact continuous blood pressure monitoring.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Optoelectronic Information and Computer Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China.
- Henan Medical College, Zhengzhou University, Zhengzhou 450001, China.
- Terahertz Spectrum and Imaging Technology, Co-Operative Innovation Center, Terahertz Technology Innovation Research Institute, University of Shanghai for Science and Technology, Shanghai 200093, China.
- Nantong Taiji Technology Co., Ltd., Nantong 226152, China.
- Shanghai Institute of Intelligent Science and Technology, Tongji University, Shanghai 200092, China.
- School of Intelligent Emergency Management, University of Shanghai for Science and Technology, Shanghai 200093, China.
Förderung
- National Natural Science Foundation of China
- Natural Science Foundation of Shanghai
- Terahertz Precision Biomedical Technology Discipline Innovation and Intelligence Project
- Key Research and Development Program of the Ministry of Science and Technology of China
Zitieren
APA
Liu, Y., Zhang, T., Luo, Y., Zhou, L., Ding, L., & Li, Y. (2026). Non-Contact Blood Pressure Prediction Using Radar with a Lightweight Temporal Multi-Scale Feature Fusion Network. Sensors, 26(11), 3468. https://doi.org/10.3390/s26113468
Vancouver
Liu Y, Zhang T, Luo Y, Zhou L, Ding L, Li Y. Non-Contact Blood Pressure Prediction Using Radar with a Lightweight Temporal Multi-Scale Feature Fusion Network. Sensors. 2026;26(11):3468. doi:10.3390/s26113468
BibTeX
@article{Liu2026,
author = {Liu, Yuhan and Zhang, Tianlin and Luo, Yonggang and Zhou, Liguo and Ding, Li and Li, Yinwei},
title = {Non-Contact Blood Pressure Prediction Using Radar with a Lightweight Temporal Multi-Scale Feature Fusion Network},
journal = {Sensors},
year = {2026},
volume = {26},
number = {11},
pages = {3468},
doi = {10.3390/s26113468}
}
EUVIMED