EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Application of a Smart Orthosis in the Treatment of Idiopathic Scoliosis—A Pilot Case Study

Patrycja Tymińska-Wójcik iD, Katarzyna Zaborowska-Sapeta iD, Tomasz Giżewski iD

Sensors · 17.05.2026 · 26 (10) · 3169

DOI: 10.3390/s26103169 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 17.05.2026. Verfasst von Patrycja Tymińska-Wójcik und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electrical Devices and High Voltage Technology, Lublin University of Technology, Nadbystrzycka 38d, 20-618 Lublin, Poland. Hauptthemen laut MEDLINE: Scoliosis, Orthotic Devices. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The increasing demand for personalized conservative treatment of idiopathic scoliosis (IS) highlights the need for objective and continuous monitoring of corrective forces during brace therapy. This study aims to evaluate the feasibility and clinical relevance of a smart orthopedic brace equipped with integrated force sensors for long-term biomechanical assessment. Three female patients with different types of idiopathic scoliosis were treated using a custom-designed thoracolumbosacral orthosis incorporating four flexible pressure sensors, enabling real-time and long-term recording of corrective forces at key anatomical locations. Sensor data were analyzed in relation to brace-wearing adherence, patient activity, and radiological outcomes assessed using Cobb angle measurements. The results demonstrated substantial variability in force distribution and wearing patterns among patients, which was associated with differences in treatment effectiveness. Higher and more stable corrective forces near curve apices were generally accompanied by improved radiological outcomes, whereas irregular brace use and uneven pressure distribution limited therapeutic effects. Long-term monitoring enabled identification of insufficient correction zones and adherence issues. In conclusion, the proposed sensor-based orthotic system provides clinically relevant information on force distribution and brace use, supporting individualized therapy optimization. These findings indicate that smart braces can enhance clinical decision-making and contribute to more effective and personalized scoliosis management.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ScoliosisOrthotic DevicesHumansFemalePilot ProjectsBracesAdolescentBiomechanical Phenomena

Stichwörter der Autor:innen

braceforce sensorsscoliosiswearable devices

Autor:innen und Institutionen

  • Department of Electrical Devices and High Voltage Technology, Lublin University of Technology, Nadbystrzycka 38d, 20-618 Lublin, Poland.
  • Department of Rehabilitation and Orthopedics, School of Medicine, University of Warmia and Mazury in Olsztyn, Michała Oczapowskiego 2, 10-719 Olsztyn, Poland.
  • Regional Specialized Children's Hospital in Olsztyn, Żołnierska 18a, 10-561 Olsztyn, Poland.
  • Department of Electrical Engineering and Superconducting Technologies, Lublin University of Technology, Nadbystrzycka 38d, 20-618 Lublin, Poland.

ORCID-Profile: Patrycja Tymińska-Wójcik, Katarzyna Zaborowska-Sapeta, Tomasz Giżewski

Zitieren

APA

Tymińska-Wójcik, P., Zaborowska-Sapeta, K., & Giżewski, T. (2026). Application of a Smart Orthosis in the Treatment of Idiopathic Scoliosis—A Pilot Case Study. Sensors, 26(10), 3169. https://doi.org/10.3390/s26103169

Vancouver

Tymińska-Wójcik P, Zaborowska-Sapeta K, Giżewski T. Application of a Smart Orthosis in the Treatment of Idiopathic Scoliosis—A Pilot Case Study. Sensors. 2026;26(10):3169. doi:10.3390/s26103169

BibTeX
@article{TymiskaWjcik2026,
  author = {Tymińska-Wójcik, Patrycja and Zaborowska-Sapeta, Katarzyna and Giżewski, Tomasz},
  title = {Application of a Smart Orthosis in the Treatment of Idiopathic Scoliosis—A Pilot Case Study},
  journal = {Sensors},
  year = {2026},
  volume = {26},
  number = {10},
  pages = {3169},
  doi = {10.3390/s26103169}
}
Kostenlos starten →