Fachartikel in der Zeitschrift Sensors, online erschienen am 15.05.2026. Verfasst von Lu HongMing und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electrical Engineering, Honam University, 417 Eodeung-daero, Gwangsan-gu, Gwangju 62399, Republic of Korea. Die Arbeit nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Institute of Information & Communications Technology Planning & Evaluation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Series arc faults on the DC side of photovoltaic (PV) systems are a critical hazard that can trigger system fires. Conventional contact-based detection methods suffer from cumbersome installation and high retrofit cost, whereas existing non-contact approaches mostly rely on megahertz-level high-frequency sampling and therefore require expensive radio-frequency instrumentation or high-performance computing platforms. As a result, it remains difficult to simultaneously achieve strong interference immunity and real-time performance on low-cost embedded devices with limited resources. To address this engineering paradox between high-frequency sampling and constrained computational capability, this paper proposes a fully embedded, non-contact arc fault detection system based on a 12–80 kHz low-frequency sub-band selection strategy. By exploiting the physical characteristic of broadband energy elevation induced by arc faults, the proposed strategy avoids dependence on high-bandwidth hardware. Guided by this strategy, a Moebius-topology coaxial shielded loop antenna is employed as the near-field sensor, while an ultra-simplified passive analog front end is constructed directly by using the on-chip programmable gain amplifier and analog-to-digital converter of the microcontroller unit, enabling efficient signal acquisition and fast Fourier transform processing within the target sub-band. To cope with complex background noise in the low-frequency range, an environment-adaptive baseline mechanism based on exponential moving average and exponential absolute deviation is developed for dynamic decoupling. In addition, a lightweight INT8-quantized multilayer perceptron is introduced as a nonlinear auxiliary module, thereby forming a robust hybrid decision architecture with complementary rule-based and artificial intelligence components. Experimental results show that, under the tested household, laboratory, and PV-site conditions, the proposed system achieved an overall detection rate of 97%, while the remaining 3% mainly corresponded to failed ignition or non-sustained arc attempts rather than persistent false triggering during normal monitoring.

Schlagwörter

Stichwörter der Autor:innen

DC arc fault detectionembedded systemslow-frequency sub-band selectionnear-field magnetic sensingphotovoltaic (PV) systemsrule-AI fusionshielded loop antenna

Autor:innen und Institutionen

  • Department of Electrical Engineering, Honam University, 417 Eodeung-daero, Gwangsan-gu, Gwangju 62399, Republic of Korea.

ORCID-Profile: Lu HongMing, Ko JaeHa

Förderung

  • Institute of Information & Communications Technology Planning & Evaluation

Zitieren

APA

HongMing, L., & JaeHa, K. (2026). Protection-Oriented Non-Intrusive Arc Fault Detection in Photovoltaic DC Systems via Rule–AI Fusion. Sensors, 26(10), 3138. https://doi.org/10.3390/s26103138

Vancouver

HongMing L, JaeHa K. Protection-Oriented Non-Intrusive Arc Fault Detection in Photovoltaic DC Systems via Rule–AI Fusion. Sensors. 2026;26(10):3138. doi:10.3390/s26103138

BibTeX
@article{HongMing2026,
  author = {HongMing, Lu and JaeHa, Ko},
  title = {Protection-Oriented Non-Intrusive Arc Fault Detection in Photovoltaic DC Systems via Rule–AI Fusion},
  journal = {Sensors},
  year = {2026},
  volume = {26},
  number = {10},
  pages = {3138},
  doi = {10.3390/s26103138}
}
Kostenlos starten →