EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Prediction of Superheated Steam Temperature in Thermal Power Plants Based on the iTransformer Model

Yiyao Zhang iD, Feng Xie, Wei Shen iD, Xingyang Li, Chase Wu iD

Sensors · 13.05.2026 · 26 (10) · 3078

DOI: 10.3390/s26103078 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 13.05.2026. Verfasst von Yiyao Zhang und 4 weiteren Autor:innen. Beteiligte Einrichtung: School of Computer Science and Technology, Zhejiang Sci-Tech University, Hangzhou 310018, China. Die Arbeit nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Accurate prediction of superheated steam temperature (SST) is critical for the safe and efficient operation of large-scale thermal power units, particularly under large load variations and high thermal inertia. This study proposes an iTransformer-based SST prediction framework (iTransformer-SST) to address limitations of conventional proportional–integral–derivative (PID) control and existing data-driven models in capturing multivariable coupling, time-delay effects, and physical consistency. Using the A-side subsystem of a 1000 MW thermal power unit, 19-dimensional process data were collected continuously over two months with a sampling interval of 2.4 s. After data preprocessing, time-lagged cross-correlation (TLCC) analysis combined with expert knowledge was employed for feature screening, resulting in ten highly relevant input variables. To enhance predictive robustness, the baseline iTransformer was augmented with a Local Temporal Convolution (LTC) module for local disturbance modeling and a physics-guided regularization term to enforce delayed monotonicity and smoothness constraints. In 240 min rolling forecasts of the final-stage superheater outlet temperature, the proposed model achieved a mean squared error (MSE) of 0.0887, a mean absolute error (MAE) of 0.2312, and a coefficient of determination (R2) of 0.9650, significantly outperforming long short-term memory (LSTM), Informer, and the baseline iTransformer. The combined LTC and physics-guided design reduced MSE by 13.5%, demonstrating strong potential for feedforward-assisted SST control in industrial thermal power applications.

Schlagwörter

Stichwörter der Autor:innen

LSTMiTransformersensorssuperheated steamtemperature predictiontime series

Autor:innen und Institutionen

  • School of Computer Science and Technology, Zhejiang Sci-Tech University, Hangzhou 310018, China.
  • Department of Data Science, New Jersey Institute of Technology, Newark, NJ 07102, USA.

ORCID-Profile: Yiyao Zhang, Wei Shen, Chase Wu

Zitieren

APA

Zhang, Y., Xie, F., Shen, W., Li, X., & Wu, C. (2026). Prediction of Superheated Steam Temperature in Thermal Power Plants Based on the iTransformer Model. Sensors, 26(10), 3078. https://doi.org/10.3390/s26103078

Vancouver

Zhang Y, Xie F, Shen W, Li X, Wu C. Prediction of Superheated Steam Temperature in Thermal Power Plants Based on the iTransformer Model. Sensors. 2026;26(10):3078. doi:10.3390/s26103078

BibTeX
@article{Zhang2026,
  author = {Zhang, Yiyao and Xie, Feng and Shen, Wei and Li, Xingyang and Wu, Chase},
  title = {Prediction of Superheated Steam Temperature in Thermal Power Plants Based on the iTransformer Model},
  journal = {Sensors},
  year = {2026},
  volume = {26},
  number = {10},
  pages = {3078},
  doi = {10.3390/s26103078}
}