Non-Contact Detection of Apnea-like Breathing Cessations Using Laser Speckle Pattern Analysis

Ayuushi Dutta iD, Amir Shemer iD, Ariel Schwarz, Yossef Danan, Yevgeny Beiderman

Sensors · 12.05.2026 · 26 (10) · 3042

DOI: 10.3390/s26103042 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 12.05.2026. Verfasst von Ayuushi Dutta und 4 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Electrical and Electronics Engineering, Holon Institute of Technology, Holon 5810201, Israel. Hauptthemen laut MEDLINE: Sleep Apnea Syndromes, Lasers, Biosensing Techniques. Die Arbeit nennt 62 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministry of Science, Israel, Ministry of Science.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Sleep apnea is a prevalent sleep-related breathing disorder characterized by recurrent cessations or reductions in airflow during sleep. It significantly impacts the quality of life, yet current diagnostic methods like polysomnography (PSG) are expensive and uncomfortable, limiting accessibility and ease of use. We developed a novel non-contact biosensing system using secondary laser speckle pattern analysis and dedicated image processing algorithms for apnea-like breathing cessations. The proposed method was tested on 14 healthy subjects with diverse body characteristics, aged 22–50 years (mean 33.1 ± 9.3 years) and body mass index (BMI) ranging from 19.6 to 28.7 kg/m2 (mean 24.6 ± 3.0 kg/m2) at different ‘simulated’ sleeping positions (back-lying, stomach-lying and side-lying), using voluntary breath-holding protocols to simulate apnea-like cessations lasting 10–20 s (short duration) and 20–30 s (long duration). To evaluate the performance of the system without selection bias, two complementary five-fold cross-validation procedures were applied: a participant-level and a class-level stratification. Using class-wise stratification, the system achieved an overall accuracy of 87.0 ± 3.0% (95% CI: [85.3%, 88.7%]), long-cessation sensitivity of 91 ± 12.4%(95% CI:[83.8%,98.2%]) and a short-cessation sensitivity of 88.0 ± 11%(95% CI:[81.6%,94.4%]). The two-class classification strategy confirm the robustness of the approach, supporting the potential of secondary laser speckle pattern analysis as a low-cost, non-contact alternative for home-based sleep apnea screening.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Sleep Apnea SyndromesLasersBiosensing TechniquesHumansAdultAlgorithmsPolysomnographyMiddle AgedFemaleMaleYoung AdultRespiration

Stichwörter der Autor:innen

non-contact sensingoptical sensingrespiratory monitorsleep apneaspeckle pattern

Autor:innen und Institutionen

  • Faculty of Electrical and Electronics Engineering, Holon Institute of Technology, Holon 5810201, Israel.
  • Department of Electronic and Electrical Engineering, Jerusalem College of Engineering, Jerusalem 9515701, Israel.

ORCID-Profile: Ayuushi Dutta, Amir Shemer

Förderung

  • Ministry of Science, Israel
  • Ministry of Science

Zitieren

APA

Dutta, A., Shemer, A., Schwarz, A., Danan, Y., & Beiderman, Y. (2026). Non-Contact Detection of Apnea-like Breathing Cessations Using Laser Speckle Pattern Analysis. Sensors, 26(10), 3042. https://doi.org/10.3390/s26103042

Vancouver

Dutta A, Shemer A, Schwarz A, Danan Y, Beiderman Y. Non-Contact Detection of Apnea-like Breathing Cessations Using Laser Speckle Pattern Analysis. Sensors. 2026;26(10):3042. doi:10.3390/s26103042

BibTeX
@article{Dutta2026,
  author = {Dutta, Ayuushi and Shemer, Amir and Schwarz, Ariel and Danan, Yossef and Beiderman, Yevgeny},
  title = {Non-Contact Detection of Apnea-like Breathing Cessations Using Laser Speckle Pattern Analysis},
  journal = {Sensors},
  year = {2026},
  volume = {26},
  number = {10},
  pages = {3042},
  doi = {10.3390/s26103042}
}
Kostenlos starten →