Electrodermal Temperature-Adjusted Electrodermal Activity (EDA) for Stress Detection in Virtual Reality

Audrey Rah iD, Yuhua Chen iD

Sensors · 09.05.2026 · 26 (10) · 2983

DOI: 10.3390/s26102983 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 09.05.2026. Verfasst von Audrey Rah und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electrical and Computer Engineering, University of Houston, Houston, TX 77204, USA. Hauptthemen laut MEDLINE: Galvanic Skin Response, Virtual Reality, Stress, Physiological. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Precise stress identification in virtual reality (VR) settings continues to be difficult because of thermoregulatory mechanisms that modify electrodermal activity (EDA) independently of emotional responses. This research presents a temperature-corrected framework that distinguishes authentic stress-induced EDA from heat-associated physiological reactions by combining two complementary thermal modeling techniques: a proportionality model and a data-driven adaptive scaling approach. Utilizing the Wearable Emotion Sensing and Detection (WESAD) dataset, temperature variations were synchronized with observed conductance patterns to adjust for thermal distortions that mask stress-specific indicators. The temperature-corrected features enhanced differentiation between stress-related and thermally influenced EDA activities, improving physiological precision and ecological authenticity. Statistical examination revealed strong distinction between affective states in both raw conductance and peripheral temperature measurements. Additionally, the adaptive scaling model produced more distinct condition-specific patterns than the proportionality method. Feature importance findings showed temperature-derived parameters as reliable contributors to classification consistency. These results emphasize temperature compensation as an essential preprocessing procedure for dependable stress identification in VR settings, allowing more accurate interpretation of EDA across different thermal circumstances.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Galvanic Skin ResponseVirtual RealityStress, PhysiologicalHumansTemperatureEmotions

Stichwörter der Autor:innen

affective computingelectrodermal activity (EDA)galvanic skin response (GSR)minimal hardware systemsreal-time systemsstress detectiontemperature adjustmentthermal compensationthermoregulationvirtual reality (VR)

Autor:innen und Institutionen

  • Department of Electrical and Computer Engineering, University of Houston, Houston, TX 77204, USA.

ORCID-Profile: Audrey Rah, Yuhua Chen

Zitieren

APA

Rah, A., & Chen, Y. (2026). Electrodermal Temperature-Adjusted Electrodermal Activity (EDA) for Stress Detection in Virtual Reality. Sensors, 26(10), 2983. https://doi.org/10.3390/s26102983

Vancouver

Rah A, Chen Y. Electrodermal Temperature-Adjusted Electrodermal Activity (EDA) for Stress Detection in Virtual Reality. Sensors. 2026;26(10):2983. doi:10.3390/s26102983

BibTeX
@article{Rah2026,
  author = {Rah, Audrey and Chen, Yuhua},
  title = {Electrodermal Temperature-Adjusted Electrodermal Activity (EDA) for Stress Detection in Virtual Reality},
  journal = {Sensors},
  year = {2026},
  volume = {26},
  number = {10},
  pages = {2983},
  doi = {10.3390/s26102983}
}
Kostenlos starten →