EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Dispersion Compensation and Multi-Beam Interference Correction Algorithm for Thickness Measurement of SiC Epitaxial Layer

Lu Liu, Weiwei Shi, Shibo Xu, Xiaofan Wang

Sensors · 08.05.2026 · 26 (10) · 2965

DOI: 10.3390/s26102965 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 08.05.2026. Verfasst von Lu Liu und 3 weiteren Autor:innen. Beteiligte Einrichtung: School of Computer Science and Engineering, Xi'an University of Technology, Xi'an 710048, China. Die Arbeit nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Beilin District Science and Technology Plan Project.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

To address the main challenges in thickness estimation of SiC epitaxial layers from infrared reflectance spectra, including refractive index dispersion, multi-beam interference, and spectral uncertainty, this study develops a physics-constrained inversion framework for reflectance spectrum-based analysis. For the measured spectra, Savitzky–Golay filtering is first used to suppress spectral noise, and Gaussian fitting is then employed to improve the localization of interference extrema. The Sellmeier equation is introduced to characterize refractive index dispersion, and the layer thickness is obtained together with the dispersion parameters through nonlinear least squares fitting. To account for spectra affected by higher-order internal reflections, a multi-feature confidence-based identification strategy is further constructed, and an adaptive filtering procedure is introduced for multi-beam interference correction. A Monte Carlo perturbation analysis with ±0.1% peak perturbations and Gaussian noise is additionally performed to assess the robustness of the inversion results. Using SiC datasets measured at two incident angles, the proposed framework reduces the inter-angle deviation of the thickness estimates from 1.14% to 0.08% after multi-beam correction. The results support the effectiveness and robustness of the proposed workflow for the main SiC application scenario considered in this study. In addition, silicon wafer spectra are included as a supplementary transfer test to examine whether the multi-beam identification and correction strategy can be applied beyond the SiC example, rather than as a comprehensive cross-material validation of the framework.

Schlagwörter

Stichwörter der Autor:innen

Monte Carlo analysisSiC epitaxial layerdispersion compensationinfrared reflectance spectramulti-beam interference correctionthickness estimation

Autor:innen und Institutionen

  • School of Computer Science and Engineering, Xi'an University of Technology, Xi'an 710048, China.
  • Shaanxi Key Laboratory of Network Computing and Security Technology, Xi'an University of Technology, Xi'an 710048, China.
  • International Engineering College, Xi'an University of Technology, Xi'an 710054, China.

Förderung

  • National Natural Science Foundation of China
  • Beilin District Science and Technology Plan Project

Zitieren

APA

Liu, L., Shi, W., Xu, S., & Wang, X. (2026). Dispersion Compensation and Multi-Beam Interference Correction Algorithm for Thickness Measurement of SiC Epitaxial Layer. Sensors, 26(10), 2965. https://doi.org/10.3390/s26102965

Vancouver

Liu L, Shi W, Xu S, Wang X. Dispersion Compensation and Multi-Beam Interference Correction Algorithm for Thickness Measurement of SiC Epitaxial Layer. Sensors. 2026;26(10):2965. doi:10.3390/s26102965

BibTeX
@article{Liu2026,
  author = {Liu, Lu and Shi, Weiwei and Xu, Shibo and Wang, Xiaofan},
  title = {Dispersion Compensation and Multi-Beam Interference Correction Algorithm for Thickness Measurement of SiC Epitaxial Layer},
  journal = {Sensors},
  year = {2026},
  volume = {26},
  number = {10},
  pages = {2965},
  doi = {10.3390/s26102965}
}
Kostenlos starten →