EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Applying Monte Carlo Method for Straight-Line Model Sensor Calibration

Pedro M Ramos iD, Fernando M Janeiro iD

Sensors · 06.05.2026 · 26 (9) · 2907

DOI: 10.3390/s26092907 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 06.05.2026. Verfasst von Pedro M Ramos und 1 weiteren Autor:innen. Beteiligte Einrichtung: Instituto de Telecomunicações, Instituto Superior Técnico, Universidade de Lisboa, Av. Rovisco Pais 1, 1049-001 Lisboa, Portugal. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Fundação para a Ciência e a Tecnologia, EU funds.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Sensors are used in measurement systems to enable estimation of physical parameters. Their calibration is an essential requirement and to perform the overall system/sensor calibration, its input is changed while the output is measured. Parameters from an appropriate sensor model are then determined from these measurements. If the model is a straight-line, a first-order least squares linear regression is commonly used to estimate the slope and offset—this is often called simple linear regression. However, this method is unable to consider uncertainty in the sensor/system input measurements. This paper reviews the possible methods to estimate the optimal straight-line parameters considering uncertainties in both input and output measurements. The Monte Carlo Method can deal with all types of uncertainties in each of the measurements, whether sensor inputs or outputs, and also take into account possible covariances of these measurements. A key aspect of this work is the application to the heteroscedastic case, where measurement uncertainties vary across observations. An MCM-based strategy is proposed to optimize the selection of new measurement input values to minimize the estimated slope uncertainty. This strategy is shown to significantly reduce, in the presented case, the number of required measurement values.

Schlagwörter

Stichwörter der Autor:innen

Monte Carlo methodcalibrationmeasurement uncertaintysensor straight-line modeluncertainty evaluationweighted total least squares regression

Autor:innen und Institutionen

  • Instituto de Telecomunicações, Instituto Superior Técnico, Universidade de Lisboa, Av. Rovisco Pais 1, 1049-001 Lisboa, Portugal.
  • Instituto de Telecomunicações, Escola de Ciências e Tecnologia, Universidade de Évora, Largo dos Colegiais 2, 7004-516 Évora, Portugal.

ORCID-Profile: Pedro M Ramos, Fernando M Janeiro

Förderung

  • Fundação para a Ciência e a Tecnologia
  • EU funds

Zitieren

APA

Ramos, P. M., & Janeiro, F. M. (2026). Applying Monte Carlo Method for Straight-Line Model Sensor Calibration. Sensors, 26(9), 2907. https://doi.org/10.3390/s26092907

Vancouver

Ramos PM, Janeiro FM. Applying Monte Carlo Method for Straight-Line Model Sensor Calibration. Sensors. 2026;26(9):2907. doi:10.3390/s26092907

BibTeX
@article{Ramos2026,
  author = {Ramos, Pedro M and Janeiro, Fernando M},
  title = {Applying Monte Carlo Method for Straight-Line Model Sensor Calibration},
  journal = {Sensors},
  year = {2026},
  volume = {26},
  number = {9},
  pages = {2907},
  doi = {10.3390/s26092907}
}
Kostenlos starten →