Analysis of Gait Biomechanics in Patients After Total Hip and Knee Arthroplasty Using Low-Cost Sensors: An Observational Repeated-Measures Study
Sensors · 28.04.2026 · 26 (9) · 2731
DOI: 10.3390/s26092731 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift Sensors, online erschienen am 28.04.2026. Verfasst von Lea Atelšek und 2 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Heatlh Sciences, University of Primorska, SI-6310 Izola, Slovenia. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Hip, Arthroplasty, Replacement, Knee, Gait. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: The Slovenian Research and Innovation Agency.
Abstract (Originalsprache)
Osteoarthritis is a leading cause of lower-limb arthroplasty, and although total hip arthroplasty (THA) and total knee arthroplasty (TKA) reduce pain and improve quality of life, gait impairments often persist after surgery. This study aimed to analyze gait patterns in individuals following THA and TKA using the wearable RunScribe™ sensor system and to examine its sensitivity to short-term changes during rehabilitation. Thirty-seven patients (19 THA, 18 TKA) attending a two-week inpatient rehabilitation program were assessed twice, on the first and final day of rehabilitation. Gait was measured during a 2 min circular walk test, and both global spatiotemporal variables and limb-specific loading-related variables were analyzed. A significant main effect of time was observed for walking speed (p = 0.001, ηp2 = 0.284), with improvements of approximately 10% in both groups, as well as for step cadence (p < 0.001, ηp2 = 0.429) and contact time (p < 0.001, ηp2 = 0.380). Loading-related variables also changed significantly over time, including impact acceleration (p = 0.004, ηp2 = 0.226), braking acceleration (p < 0.001, ηp2 = 0.419), and rate of force development (p < 0.001, ηp2 = 0.412). No statistically significant between-group differences were observed for global gait variables, although participants following THA showed a tendency toward better walking performance (e.g., higher cadence, p = 0.065). These findings suggest that early rehabilitation is associated with measurable improvements in gait after arthroplasty and support the potential of affordable wearable sensors as practical tools for objective gait assessment in clinical settings.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Faculty of Heatlh Sciences, University of Primorska, SI-6310 Izola, Slovenia.
- Ludwig Boltzmann Institute for Rehabilitation Research, A-1140 Vienna, Austria.
ORCID-Profile: Matic Sašek, Žiga Kozinc
Förderung
- The Slovenian Research and Innovation Agency
Zitieren
APA
Atelšek, L., Sašek, M., & Kozinc, Ž. (2026). Analysis of Gait Biomechanics in Patients After Total Hip and Knee Arthroplasty Using Low-Cost Sensors: An Observational Repeated-Measures Study. Sensors, 26(9), 2731. https://doi.org/10.3390/s26092731
Vancouver
Atelšek L, Sašek M, Kozinc Ž. Analysis of Gait Biomechanics in Patients After Total Hip and Knee Arthroplasty Using Low-Cost Sensors: An Observational Repeated-Measures Study. Sensors. 2026;26(9):2731. doi:10.3390/s26092731
BibTeX
@article{Atelek2026,
author = {Atelšek, Lea and Sašek, Matic and Kozinc, Žiga},
title = {Analysis of Gait Biomechanics in Patients After Total Hip and Knee Arthroplasty Using Low-Cost Sensors: An Observational Repeated-Measures Study},
journal = {Sensors},
year = {2026},
volume = {26},
number = {9},
pages = {2731},
doi = {10.3390/s26092731}
}
EUVIMED