EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Demagnetization Severity Detection in Permanent Magnet Synchronous Motors Based on Temperature Signal and Convolutional Neural Network

Zhiqiang Wang, Shihao Yan, Haodong Sun, Xin Gu iD, Zhichen Lin iD, Kefei Zhu

Sensors · 24.04.2026 · 26 (9) · 2631

DOI: 10.3390/s26092631 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 24.04.2026. Verfasst von Zhiqiang Wang und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of Electrical Engineering, Tiangong University, Tianjin 300387, China. Die Arbeit nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Key R&D Program of China, Zhejiang Provincial Natural Science Foundation, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

To address the difficulty of detecting demagnetization severity in permanent magnet synchronous motors (PMSMs), this paper proposes a demagnetization severity detection method based on temperature signal and Convolutional Neural Network (CNN). First, the differences between local demagnetization and eccentricity fault in stator current harmonics are analyzed from an electromagnetic perspective, and fast Fourier transform (FFT) is used for frequency-domain analysis of the stator current to identify local demagnetization faults. On this basis, an electromagnetic–thermal coupling model is established by considering motor losses and heat dissipation boundary conditions to obtain the winding temperatures under different demagnetization severities and operating conditions. Furthermore, the temperature time series, together with speed and load torque, is constructed into a three-dimensional state space, and the proposed Conditionally Modulated Multi-Scale Convolutional Neural Network (CMSCNN) is introduced for feature learning to achieve demagnetization severity detection. Experimental results show that the proposed method achieves an average detection accuracy of 98.06% on the simulation test set and outperforms the baseline CNN model. On measured data collected from the faulty prototype, the average detection accuracy reaches 93.34%, verifying the effectiveness of the proposed method for demagnetization severity detection.

Schlagwörter

Stichwörter der Autor:innen

Convolutional Neural Networkdemagnetization severity detectionlocal demagnetizationpermanent magnet synchronous motortemperature

Autor:innen und Institutionen

  • School of Electrical Engineering, Tiangong University, Tianjin 300387, China.
  • Zhejiang University Advanced Electrical Equipment Innovation Center, Hangzhou 311107, China.
  • Shanghai Electric Drive Co., Ltd., Shanghai 200240, China.
  • School of Mechatronic Engineering and Automation, Shanghai University, Shanghai 200444, China.

ORCID-Profile: Xin Gu, Zhichen Lin

Förderung

  • National Key R&D Program of China
  • Zhejiang Provincial Natural Science Foundation
  • National Natural Science Foundation of China
  • Zhejiang Provincial Natural Science Foundation of China

Zitieren

APA

Wang, Z., Yan, S., Sun, H., Gu, X., Lin, Z., & Zhu, K. (2026). Demagnetization Severity Detection in Permanent Magnet Synchronous Motors Based on Temperature Signal and Convolutional Neural Network. Sensors, 26(9), 2631. https://doi.org/10.3390/s26092631

Vancouver

Wang Z, Yan S, Sun H, Gu X, Lin Z, Zhu K. Demagnetization Severity Detection in Permanent Magnet Synchronous Motors Based on Temperature Signal and Convolutional Neural Network. Sensors. 2026;26(9):2631. doi:10.3390/s26092631

BibTeX
@article{Wang2026,
  author = {Wang, Zhiqiang and Yan, Shihao and Sun, Haodong and Gu, Xin and Lin, Zhichen and Zhu, Kefei},
  title = {Demagnetization Severity Detection in Permanent Magnet Synchronous Motors Based on Temperature Signal and Convolutional Neural Network},
  journal = {Sensors},
  year = {2026},
  volume = {26},
  number = {9},
  pages = {2631},
  doi = {10.3390/s26092631}
}
Kostenlos starten →