Smart Sensor-Driven Gait Rehabilitation Walker Using Machine Learning for Predictive Home-Based Therapy
Sensors · 21.04.2026 · 26 (8) · 2547
DOI: 10.3390/s26082547 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 21.04.2026. Verfasst von Gokul Manavalan und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, Rajalakshmi Engineering College, Chennai 602105, India. Hauptthemen laut MEDLINE: Gait, Machine Learning, Walkers. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 65 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Kreitman School of Advanced Graduate Studies, Ben-Gurion University of the Negev.
Abstract (Originalsprache)
Abnormal gait associated with neuromuscular and musculoskeletal disorders represents a growing clinical burden, particularly in aging populations. This study presents a modular, low-cost Smart Rehabilitation Walker (SRW) that integrates multimodal sensing and real-time haptic feedback to enable simultaneous gait monitoring and corrective intervention in both clinical and home environments. The system combines force-sensing resistors for bilateral load symmetry assessment, inertial measurement units for fall detection, and surface electromyography (sEMG) for neuromuscular activity monitoring within a closed-loop assistive feedback architecture. A 15-day pilot study involving ten individuals with rheumatoid arthritis and clinically observed neurological gait abnormalities demonstrated measurable improvements in gait biomechanics. The Force Symmetry Index (FSI), calculated using the Robinson symmetry metric, decreased from an average of 0.9691 to 0.2019, corresponding to a 79.26% average reduction in inter-limb load asymmetry. Concurrently, sEMG measurements showed a substantial increase in neuromuscular activation (ΔEMG = 4.28), with statistical analysis confirming a significant improvement across participants (paired t-test: t(9) = 13.58, p < 0.001). To model rehabilitation trajectories, a nonlinear predictive framework based on Gaussian Process Regression achieved high predictive accuracy (R2 ≈ 0.9, with a mean RMSE of 0.0385), while providing uncertainty-aware trend estimation. Validation using an independent amyotrophic lateral sclerosis gait dataset further demonstrated the transferability of the analytical pipeline. These results highlight the potential of sensor-enabled assistive walkers as scalable platforms for quantitative gait rehabilitation, adaptive feedback, and long-term mobility monitoring.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Biomedical Engineering, Rajalakshmi Engineering College, Chennai 602105, India.
- Electrical and Computer Engineering Department, Ben-Gurion University of the Negev, Beer Sheva 8410501, Israel.
- Medical School for International Health, Ben-Gurion University of the Negev, Beer Sheva 8410501, Israel.
ORCID-Profile: Gokul Manavalan, Shlomi Arnon
Förderung
- Kreitman School of Advanced Graduate Studies
- Ben-Gurion University of the Negev
Zitieren
APA
Manavalan, G., Arnon, Y., Nithyaa, A. N., & Arnon, S. (2026). Smart Sensor-Driven Gait Rehabilitation Walker Using Machine Learning for Predictive Home-Based Therapy. Sensors, 26(8), 2547. https://doi.org/10.3390/s26082547
Vancouver
Manavalan G, Arnon Y, Nithyaa AN, Arnon S. Smart Sensor-Driven Gait Rehabilitation Walker Using Machine Learning for Predictive Home-Based Therapy. Sensors. 2026;26(8):2547. doi:10.3390/s26082547
BibTeX
@article{Manavalan2026,
author = {Manavalan, Gokul and Arnon, Yuval and Nithyaa, A N and Arnon, Shlomi},
title = {Smart Sensor-Driven Gait Rehabilitation Walker Using Machine Learning for Predictive Home-Based Therapy},
journal = {Sensors},
year = {2026},
volume = {26},
number = {8},
pages = {2547},
doi = {10.3390/s26082547}
}
EUVIMED