EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Global Calibration of a Collaborative Multi-Line-Scan Camera Measurement System

Yuanshen Xie, Nanhui Wu iD, Yueqiao Hou, Weixin Xu, Jiangjie Yu, Zichao Yin, Dapeng Tan iD

Sensors · 17.04.2026 · 26 (8) · 2498

DOI: 10.3390/s26082498 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 17.04.2026. Verfasst von Yuanshen Xie und 6 weiteren Autor:innen. Beteiligte Einrichtung: College of Mechanical Engineering, Zhejiang University of Technology, Hangzhou 310014, China. Die Arbeit nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Zhejiang Provincial Natural Science Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Multi-line-scan camera systems provide high-frequency sampling and wide field-of-view coverage, making them valuable for three-dimensional measurement and dynamic reconstruction. However, their one-dimensional projection property introduces scale ambiguity and strong parameter coupling during calibration, which limits the consistency and stability of local optimization in multi-camera systems. To address this issue, this paper proposes a global calibration method based on physical constraints and hierarchical optimization. A unified imaging and motion model is constructed by incorporating physical scale constraints and structural priors, and geometric scale information is introduced into the joint optimization to reduce scale ambiguity and parameter coupling. Parameter normalization and staged optimization are further adopted to improve numerical stability for variables of different magnitudes and enable consistent estimation of multi-camera parameters within a unified framework. Simulation and experimental results show that the method achieves stable convergence under focal-length initialization perturbation, baseline deviation, and noise interference, with a three-dimensional reconstruction error below 0.67 mm and a convergence probability of at least 99.7%. These results indicate that the proposed method effectively reduces calibration uncertainty in multi-line-scan camera systems and supports high-precision online measurement and dynamic three-dimensional perception.

Schlagwörter

Stichwörter der Autor:innen

geometric constraintsglobal calibrationhierarchical optimizationmulti-line-scan camera systemthree-dimensional measurement

Autor:innen und Institutionen

  • College of Mechanical Engineering, Zhejiang University of Technology, Hangzhou 310014, China.
  • Quzhou Eco-Industrial Innovation Institute ZJUT, Quzhou 324499, China.

ORCID-Profile: Nanhui Wu, Dapeng Tan

Förderung

  • Zhejiang Provincial Natural Science Foundation

Zitieren

APA

Xie, Y., Wu, N., Hou, Y., Xu, W., Yu, J., Yin, Z., & Tan, D. (2026). Global Calibration of a Collaborative Multi-Line-Scan Camera Measurement System. Sensors, 26(8), 2498. https://doi.org/10.3390/s26082498

Vancouver

Xie Y, Wu N, Hou Y, Xu W, Yu J, Yin Z, et al. Global Calibration of a Collaborative Multi-Line-Scan Camera Measurement System. Sensors. 2026;26(8):2498. doi:10.3390/s26082498

BibTeX
@article{Xie2026,
  author = {Xie, Yuanshen and Wu, Nanhui and Hou, Yueqiao and Xu, Weixin and Yu, Jiangjie and Yin, Zichao and Tan, Dapeng},
  title = {Global Calibration of a Collaborative Multi-Line-Scan Camera Measurement System},
  journal = {Sensors},
  year = {2026},
  volume = {26},
  number = {8},
  pages = {2498},
  doi = {10.3390/s26082498}
}
Kostenlos starten →