Test–Retest Reliability of Heart Rate and Parasympathetic Modulation Indices Across Exercise and Recovery Phases in Athletes
Sensors · 16.04.2026 · 26 (8) · 2448
DOI: 10.3390/s26082448 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 16.04.2026. Verfasst von Süleyman Ulupınar und 7 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Sports Sciences, Erzurum Technical University, Erzurum 25050, Türkiye. Hauptthemen laut MEDLINE: Heart Rate, Parasympathetic Nervous System, Athletes, Exercise. Die Arbeit nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: TÜBİTAK 2209—University Students Research Projects Support Program, Scientific Research Projects Coordination Unit of Istanbul Yeni Yuzyil University.
Abstract (Originalsprache)
This study examined the within-session (same-day) test–retest reliability of heart rate (HR) and parasympathetic modulation, assessed using the root mean square of successive differences (RMSSD), across exercise and recovery phases in trained soccer players. Twenty-seven male soccer players (age: 24.9 ± 3.7 years) completed a standardized soccer training session. HR and RMSSD were recorded using an ECG-based chest-strap monitor at rest, pre-exercise, and at ~10–20 min, 1 h, and 3 h post-exercise. At each time point, two consecutive 5 min seated recordings were obtained under identical conditions. Test–retest reliability was evaluated using intraclass correlation coefficients (ICC(3,1)), standard error of measurement (SEM), coefficient of variation (CV%), minimal detectable change (MDC95), paired-samples t-tests, and Hedges’ g effect sizes. HR demonstrated excellent reliability across all time points (ICC = 0.980–0.994; SEM = 0.87–1.25 bpm; CV% = 1.33–3.70%). RMSSD showed excellent reliability at rest (ICC = 0.944) and pre-exercise (ICC = 0.918), moderate reliability during early recovery (~10–20 min; ICC = 0.551), and good reliability at 1 h (ICC = 0.826) and 3 h post-exercise (ICC = 0.873). No significant systematic differences were observed between test and retest measurements (all p > 0.05), and effect sizes were trivial. These findings indicate that within-session reliability of HR remains consistently high across exercise and recovery phases, whereas RMSSD reliability varies according to measurement timing, particularly during early recovery.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Faculty of Sports Sciences, Erzurum Technical University, Erzurum 25050, Türkiye.
- Faculty of Sports Sciences, Ankara Yıldırım Beyazıt University, Ankara 06010, Türkiye.
- Faculty of Sports Sciences, Istanbul University-Cerrahpaşa, Istanbul 34320, Türkiye.
- Faculty of Sports Sciences, Istanbul Yeni Yuzyil University, Istanbul 34010, Türkiye.
ORCID-Profile: Süleyman Ulupınar, Salih Çabuk, Abdullah Demirli, Kaan Kaya
Förderung
- TÜBİTAK 2209—University Students Research Projects Support Program
- Scientific Research Projects Coordination Unit of Istanbul Yeni Yuzyil University
Zitieren
APA
Ulupınar, S., Özbay, S., Gençoğlu, C., İnce, İ., Çabuk, S., Bakar, Ö., Demirli, A., & Kaya, K. (2026). Test–Retest Reliability of Heart Rate and Parasympathetic Modulation Indices Across Exercise and Recovery Phases in Athletes. Sensors, 26(8), 2448. https://doi.org/10.3390/s26082448
Vancouver
Ulupınar S, Özbay S, Gençoğlu C, İnce İ, Çabuk S, Bakar Ö, et al. Test–Retest Reliability of Heart Rate and Parasympathetic Modulation Indices Across Exercise and Recovery Phases in Athletes. Sensors. 2026;26(8):2448. doi:10.3390/s26082448
BibTeX
@article{Ulupnar2026,
author = {Ulupınar, Süleyman and Özbay, Serhat and Gençoğlu, Cebrail and İnce, İzzet and Çabuk, Salih and Bakar, Özgür and Demirli, Abdullah and Kaya, Kaan},
title = {Test–Retest Reliability of Heart Rate and Parasympathetic Modulation Indices Across Exercise and Recovery Phases in Athletes},
journal = {Sensors},
year = {2026},
volume = {26},
number = {8},
pages = {2448},
doi = {10.3390/s26082448}
}
EUVIMED