EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Optimal Sensor Placement in Buildings: Earthquake Excitation

Farid Ghahari iD, Daniel Swensen, Hamid Haddadi

Sensors · 13.04.2026 · 26 (8) · 2383

DOI: 10.3390/s26082383 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 13.04.2026. Verfasst von Farid Ghahari und 2 weiteren Autor:innen. Beteiligte Einrichtung: California Geological Survey, Sacramento, CA 95814, USA. Die Arbeit nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study presents a methodology for determining the optimal placement of seismic sensors along the height of buildings to minimize the uncertainty in reconstructing structural responses at non-instrumented floors. Due to the extensive benefits of instrumentation—from model validation to damage detection and structural health monitoring—the number of instrumented structures is steadily increasing. However, to keep installation and maintenance costs within a reasonable range, structures are often instrumented sparsely. The response at non-instrumented locations is typically estimated using deterministic or probabilistic model-based, data-driven, or hybrid methods. Specifically, the authors recently proposed a method that combines a deterministic beam model with Gaussian Process Regression (GPR) to estimate responses at non-instrumented floors of an instrumented building. The present paper proposes a methodology to determine optimal sensor locations that minimize the uncertainty associated with this response estimation. This work is a sequel to a previous study that was limited to stationary excitation and extends the method to seismic excitations. The methodology is first verified through a numerical example and then applied to two real instrumented buildings. The results demonstrate that an average 40% reduction in uncertainty is achievable when sensors are positioned according to the proposed optimization approach, in comparison with a random distribution of sensors. Between the two real-life cases studied in this paper, the level of reduction in the response uncertainty is around 10% for the 52-story building because the existing sensors are almost uniformly distributed, while it is around 80% for the 73-story building because the existing sensors are distributed to measure the localized behavior of the building.

Schlagwörter

Stichwörter der Autor:innen

Gaussian Process Regressionbeam modelbuildingsearthquake responseoptimal sensor placement

Autor:innen und Institutionen

  • California Geological Survey, Sacramento, CA 95814, USA.
  • The B. John Garrick Institute for the Risk Sciences, University of California, Los Angeles, CA 90095, USA.

ORCID-Profile: Farid Ghahari

Zitieren

APA

Ghahari, F., Swensen, D., & Haddadi, H. (2026). Optimal Sensor Placement in Buildings: Earthquake Excitation. Sensors, 26(8), 2383. https://doi.org/10.3390/s26082383

Vancouver

Ghahari F, Swensen D, Haddadi H. Optimal Sensor Placement in Buildings: Earthquake Excitation. Sensors. 2026;26(8):2383. doi:10.3390/s26082383

BibTeX
@article{Ghahari2026,
  author = {Ghahari, Farid and Swensen, Daniel and Haddadi, Hamid},
  title = {Optimal Sensor Placement in Buildings: Earthquake Excitation},
  journal = {Sensors},
  year = {2026},
  volume = {26},
  number = {8},
  pages = {2383},
  doi = {10.3390/s26082383}
}