EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A Cheonjiin Layout Mental Speller: Developing a Simple and Cost-Effective EEG-Based Brain–Computer Interface System

Ji Won Ahn, Gi Yeon Yu, Seong-Wan Kim, Young-Seek Seok, Kyung-Min Byun, Seung Ho Choi

Sensors · 07.04.2026 · 26 (7) · 2265

DOI: 10.3390/s26072265 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 07.04.2026. Verfasst von Ji Won Ahn und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, Yonsei University, Wonju 26493, Republic of Korea. Hauptthemen laut MEDLINE: Brain-Computer Interfaces, Electroencephalography. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 58 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Rural Development Administration, Ministry of Science and ICT, Rural Development Administration, Republic of Korea.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A brain–computer interface (BCI) enables direct communication between the brain and external devices by translating neural activity into executable control commands. Among electroencephalography (EEG)-based paradigms, steady-state visual evoked potential (SSVEP) is widely adopted due to its high signal-to-noise ratio, robustness, and minimal calibration requirements. While SSVEP-based spellers have been extensively investigated, many existing systems rely on high-channel-density EEG recordings and computationally complex processing pipelines, and are primarily designed for alphabetic input structures. In this study, we present an SSVEP-based Korean speller that integrates the Cheonjiin keyboard layout to support intuitive composition of Hangul syllables. The proposed system adopts a simple configuration, employing only five visual stimulation frequencies (6.67–12 Hz) and two occipital EEG channels (O1 and O2), with real-time frequency recognition performed using canonical correlation analysis (CCA) within a 1.5 s sliding window. EEG signals were acquired at 200 Hz using an OpenBCI Ganglion board, band-pass filtered (5–45 Hz), and processed with harmonic sinusoidal reference templates for multi-frequency classification. The proposed interface generates five control commands (up, down, left, right, and select), enabling directional cursor navigation and character confirmation on a 4 × 4 virtual Cheonjiin keyboard. Experimental validation with three healthy participants demonstrated an average classification accuracy of approximately 82% and an information transfer rate (ITR) of 31.2 bits/min. Frequency-domain analysis revealed clear spectral peaks at the stimulation frequencies and their harmonics, indicating reliable SSVEP responses. The proposed system employs a simple two-channel configuration integrated with a Korean language-specific input structure, demonstrating that reliable SSVEP-based communication can be realized without computationally intensive algorithms or high-cost EEG acquisition systems. These findings demonstrate that reliable SSVEP-based communication can be achieved using a low-channel configuration without reliance on high-cost EEG equipment.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Brain-Computer InterfacesElectroencephalographyHumansEvoked Potentials, VisualSignal Processing, Computer-AssistedCost-Benefit Analysis

Stichwörter der Autor:innen

Cheonjiin keyboardbrain–computer interface (BCI)directional inputelectroencephalography (EEG)speller system

Autor:innen und Institutionen

  • Department of Biomedical Engineering, Yonsei University, Wonju 26493, Republic of Korea.
  • Department of Agricultural Biology, National Institute of Agricultural Sciences, Rural Development Administration, Wanju 55365, Republic of Korea.
  • Gangwon-do Agricultural Product Registered Seed Station, Chuncheon 24410, Republic of Korea.
  • Department of Biomedical Engineering, College of Electronics and Information, Kyung Hee University, Yongin 17104, Republic of Korea.
  • Department of Electronics and Information Convergence Engineering, Kyung Hee University, Yongin 17104, Republic of Korea.
  • Department of Integrative Medicine, Major in Digital Healthcare, Yonsei University College of Medicine, Seoul 06229, Republic of Korea.

Förderung

  • Rural Development Administration
  • Ministry of Science and ICT
  • Rural Development Administration, Republic of Korea

Zitieren

APA

Ahn, J. W., Yu, G. Y., Kim, S. W., Seok, Y. S., Byun, K. M., & Choi, S. H. (2026). A Cheonjiin Layout Mental Speller: Developing a Simple and Cost-Effective EEG-Based Brain–Computer Interface System. Sensors, 26(7), 2265. https://doi.org/10.3390/s26072265

Vancouver

Ahn JW, Yu GY, Kim SW, Seok YS, Byun KM, Choi SH. A Cheonjiin Layout Mental Speller: Developing a Simple and Cost-Effective EEG-Based Brain–Computer Interface System. Sensors. 2026;26(7):2265. doi:10.3390/s26072265

BibTeX
@article{Ahn2026,
  author = {Ahn, Ji Won and Yu, Gi Yeon and Kim, Seong-Wan and Seok, Young-Seek and Byun, Kyung-Min and Choi, Seung Ho},
  title = {A Cheonjiin Layout Mental Speller: Developing a Simple and Cost-Effective EEG-Based Brain–Computer Interface System},
  journal = {Sensors},
  year = {2026},
  volume = {26},
  number = {7},
  pages = {2265},
  doi = {10.3390/s26072265}
}
Kostenlos starten →