EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Estimation of the Knee Joint with Single-Camera Smartphone

Michela Russo iD, Carlo Ricciardi iD, Maria Romano iD, Vittorio Santoriello iD, Alfonso Maria Ponsiglione iD, Francesco Amato iD, Maria Francesca Spadea iD

Sensors · 31.03.2026 · 26 (7) · 2148

DOI: 10.3390/s26072148 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 31.03.2026. Verfasst von Michela Russo und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemical, Material and Industrial Production Engineering, University of Naples Federico II, 80125 Naples, Italy. Hauptthemen laut MEDLINE: Smartphone, Knee Joint, Gait Analysis. Die Arbeit nennt 55 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Union under the Italian National Recovery and Resilience Plan (NRRP) of NextGenerationEU, partnership on "Telecommunications of the Future", European Union.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

(1)

Background

Gait analysis provides quantitative information on walking patterns and has proven invaluable for assessing motor function in rehabilitation programmes. A markerless motion capture system combining computer vision techniques provides low-cost, real-time, portable gait analysis. (2)

Methods

The kinematics of the knee and ankle of twenty-seven healthy volunteers were assessed using a single smartphone camera combined with the MediaPipe human pose estimation framework. The system was validated using the OPAL wearable sensor system by APDM Wearable Technologies. (3)

Results

Findings showed close correspondence between the two systems for knee kinematics showing a mean absolute error of 4.10° ± 2.32° and 3.15° ± 3.10° for right and left knee flexion, respectively, and a mean absolute error of 2.30° ± 2.01° and 3.12° ± 2.63° for right and left knee extension, respectively. The mean absolute error for right and left knee range of motion was found to be 4.55° ± 3.12° and 4.15° ± 3.01°, respectively. Moreover, Bland–Altman plots indicated minimal bias (average 0.6 for flexion, average 0.47 for the extension, and 0.30 for the range of motion) and excellent correlation for knee flexion bilaterally (0.916 and 0.845 for the right and left side, respectively), with slightly lower but still satisfactory agreement for knee extension (0.862 and 0.845 for the right and left side, respectively). Conversely, ankle measurements revealed poor concordance: dorsiflexion and range of motion presented significant differences and systematic errors, while plantarflexion showed no statistical difference but weak correlation. (4)

Conclusions

This study demonstrated that combining a smartphone camera with a human pose estimation framework allows for low-cost, real-time, portable gait analysis, particularly of the knee joint.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SmartphoneKnee JointGait AnalysisHumansMotion CaptureRange of Motion, ArticularBiomechanical PhenomenaFemaleAdultMaleGaitWearable Electronic Devices

Stichwörter der Autor:innen

gait analysismarkerless motion capturesignal processingsmartphone single-cameravideo-based analysiswearable sensors

Autor:innen und Institutionen

  • Department of Chemical, Material and Industrial Production Engineering, University of Naples Federico II, 80125 Naples, Italy.
  • Department of Electrical Engineering and Information Technology, University of Naples Federico II, 80125 Naples, Italy.
  • Institute of Biomedical and Neural Engineering, Reykjavik University, 102 Reykjavik, Iceland.
  • Institute of Biomedical Engineering, Karlsruhe Institute of Technology, 76131 Baden-Württemberg, Germany.

ORCID-Profile: Michela Russo, Carlo Ricciardi, Maria Romano, Vittorio Santoriello, Alfonso Maria Ponsiglione, Francesco Amato, Maria Francesca Spadea

Förderung

  • European Union under the Italian National Recovery and Resilience Plan (NRRP) of NextGenerationEU, partnership on "Telecommunications of the Future"
  • European Union

Zitieren

APA

Russo, M., Ricciardi, C., Romano, M., Santoriello, V., Ponsiglione, A. M., Amato, F., & Spadea, M. F. (2026). Estimation of the Knee Joint with Single-Camera Smartphone. Sensors, 26(7), 2148. https://doi.org/10.3390/s26072148

Vancouver

Russo M, Ricciardi C, Romano M, Santoriello V, Ponsiglione AM, Amato F, et al. Estimation of the Knee Joint with Single-Camera Smartphone. Sensors. 2026;26(7):2148. doi:10.3390/s26072148

BibTeX
@article{Russo2026,
  author = {Russo, Michela and Ricciardi, Carlo and Romano, Maria and Santoriello, Vittorio and Ponsiglione, Alfonso Maria and Amato, Francesco and Spadea, Maria Francesca},
  title = {Estimation of the Knee Joint with Single-Camera Smartphone},
  journal = {Sensors},
  year = {2026},
  volume = {26},
  number = {7},
  pages = {2148},
  doi = {10.3390/s26072148}
}
Kostenlos starten →