Radar-Based Monitoring: A Proof of Principle Study in a Piglet Model for a Novel Approach in Non-Contact Vital Sign Monitoring
Sensors · 30.03.2026 · 26 (7) · 2139
DOI: 10.3390/s26072139 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 30.03.2026. Verfasst von Sybelle Goedicke-Fritz und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of General Pediatrics and Neonatology, Saarland University, Campus Homburg, 66421 Homburg, Germany. Hauptthemen laut MEDLINE: Radar, Vital Signs. Die Arbeit nennt 86 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: German Federal Ministry of Education and Research.
Abstract (Originalsprache)
(1)
Background
Hospitalized preterm infants often require months of vital signs monitoring in the neonatal intensive care unit. Today, wired sensors are essential for survival, but are associated with numerous disadvantages including sensor dislocations, skin trauma and hygiene risks. Non-contact vital sign monitoring would therefore represent a significant improvement in the care of hospitalized neonates. (2)
Objective
This study aims to lay the foundation for non-contact radar-based monitoring of the respiratory rate, which could be used in the neonatal intensive care unit. (3)
Methods
We developed a radar-based vital parameter monitoring system for recording the respiratory rate of premature infants in a pediatric incubator. The novel system employs a four-channel I/Q FMCW radar with compact, application-specific antennas optimized to cover the defined area of interest on the infant’s thorax. As a proof-of-principle study, the system was tested in six anesthetized newborn piglets. (4)
Results
Using the radar-based system, thorax movements were detected and the respiratory rate was calculated. We observed a high accordance between the signals of respiration detected by the novel radar sensor with the signals of the cable-bound monitor in resting piglets. (5)
Conclusions
The novel radar sensor is suited for measuring respiration in the piglet model. In future, the sensor should be optimized in order to improve its robustness against disturbances body movements and in order to allow detection of heartbeat.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of General Pediatrics and Neonatology, Saarland University, Campus Homburg, 66421 Homburg, Germany.
- Laboratory of Applied Radar Technology and Optical Systems (LaROS), Trier University of Applied Sciences, Schneidershof, 54293 Trier, Germany.
- Institute for Clinical and Experimental Surgery, Saarland University, 66421 Homburg, Germany.
ORCID-Profile: Sybelle Goedicke-Fritz, René Thull, Matthias W Laschke, Erol Tutdibi, Nasenien Nourkami-Tutdibi, Michael Zemlin
Förderung
- German Federal Ministry of Education and Research
Zitieren
APA
Goedicke-Fritz, S., Schmiech, D., Thull, R., Kaiser, E., Körbel, C., Laschke, M. W., Marnach, A., Müller, S., Tutdibi, E., Nourkami-Tutdibi, N., Weber, R., Zemlin, M., & Diewald, A. R. (2026). Radar-Based Monitoring: A Proof of Principle Study in a Piglet Model for a Novel Approach in Non-Contact Vital Sign Monitoring. Sensors, 26(7), 2139. https://doi.org/10.3390/s26072139
Vancouver
Goedicke-Fritz S, Schmiech D, Thull R, Kaiser E, Körbel C, Laschke MW, et al. Radar-Based Monitoring: A Proof of Principle Study in a Piglet Model for a Novel Approach in Non-Contact Vital Sign Monitoring. Sensors. 2026;26(7):2139. doi:10.3390/s26072139
BibTeX
@article{GoedickeFritz2026,
author = {Goedicke-Fritz, Sybelle and Schmiech, Daniel and Thull, René and Kaiser, Elisabeth and Körbel, Christina and Laschke, Matthias W and Marnach, Aly and Müller, Simon and Tutdibi, Erol and Nourkami-Tutdibi, Nasenien and Weber, Regine and Zemlin, Michael and Diewald, Andreas R},
title = {Radar-Based Monitoring: A Proof of Principle Study in a Piglet Model for a Novel Approach in Non-Contact Vital Sign Monitoring},
journal = {Sensors},
year = {2026},
volume = {26},
number = {7},
pages = {2139},
doi = {10.3390/s26072139}
}