Ultrasonic Testing of Laser Welds in Medium-Thick Titanium Alloy Plates
Sensors · 27.03.2026 · 26 (7) · 2085
DOI: 10.3390/s26072085 ↗Kurz gefasst
Fachartikel in der Zeitschrift Sensors, online erschienen am 27.03.2026. Verfasst von Chenju Zhou und 5 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Extreme Environment Optoelectronic Dynamic Measurement Technology and Instrument, North University of China, Taiyuan 030051, …. Die Arbeit nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Research on the fundamental theory and methods of robust integrated navigation oriented to-wards multi-source complex interference environments, Research on the fundamental theory and methods of robust integrated navigation oriented towards multi-source complex interference environments.
Abstract (Originalsprache)
To address the challenge of detecting internal defects in medium-thick titanium alloy laser welds, a combined simulation and experimental study on ultrasonic testing was conducted. A finite element model employing a 5 MHz shear wave angle transducer for inspecting titanium alloy welds was established. An ultrasonic testing system was developed, incorporating a DPR300 pulser-receiver (JSR Ultrasonics, Pittsford, NY, USA) and an MSO5204 oscilloscope (RIGOL, Suzhou, China), and was calibrated using standard reference blocks. The inspection results for four prefabricated internal defects at various depths demonstrated that all defects were effectively detected, with the minimum detectable equivalent defect size reaching 1 mm. The measured signal-to-noise ratio (SNR) averaged 17.6 dB, validating the high sensitivity of the proposed system. The mean absolute error for defect localization was 0.438 mm, achieving a positioning accuracy better than 0.5 mm. This study indicates that the pro-posed method enables effective detection and accurate localization of internal defects in titanium alloy laser welds, providing critical technical support for laser welding quality assessment.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- State Key Laboratory of Extreme Environment Optoelectronic Dynamic Measurement Technology and Instrument, North University of China, Taiyuan 030051, China.
ORCID-Profile: Shunmin Yang
Förderung
- Research on the fundamental theory and methods of robust integrated navigation oriented to-wards multi-source complex interference environments
- Research on the fundamental theory and methods of robust integrated navigation oriented towards multi-source complex interference environments
Zitieren
APA
Zhou, C., Li, J., Yang, S., Hu, C., Feng, K., & Bo, Y. (2026). Ultrasonic Testing of Laser Welds in Medium-Thick Titanium Alloy Plates. Sensors, 26(7), 2085. https://doi.org/10.3390/s26072085
Vancouver
Zhou C, Li J, Yang S, Hu C, Feng K, Bo Y. Ultrasonic Testing of Laser Welds in Medium-Thick Titanium Alloy Plates. Sensors. 2026;26(7):2085. doi:10.3390/s26072085
BibTeX
@article{Zhou2026,
author = {Zhou, Chenju and Li, Jie and Yang, Shunmin and Hu, Chenjun and Feng, Kaiqiang and Bo, Yi},
title = {Ultrasonic Testing of Laser Welds in Medium-Thick Titanium Alloy Plates},
journal = {Sensors},
year = {2026},
volume = {26},
number = {7},
pages = {2085},
doi = {10.3390/s26072085}
}