AI-Enabled Sensor Technologies for Remote Arrhythmic Monitoring in High-Risk Cardiomyopathy Genotypes
Sensors · 26.03.2026 · 26 (7) · 2078
DOI: 10.3390/s26072078 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Sensors, online erschienen am 26.03.2026. Verfasst von Nardi Tetaj und 8 weiteren Autor:innen. Beteiligte Einrichtung: Cardiology Unit, Policlinico Universitario Campus Bio-Medico, Via Alvaro del Portillo 200, 00128 Rome, Italy. Hauptthemen laut MEDLINE: Cardiomyopathies, Arrhythmias, Cardiac, Artificial Intelligence, Biosensing Techniques. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 125 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Inherited cardiomyopathies associated with high-risk genotypes, are characterized by a disproportionate risk of malignant ventricular arrhythmias and sudden cardiac death, often independent of left ventricular systolic dysfunction or advanced structural remodeling. Traditional surveillance strategies based on intermittent electrocardiography and phenotype-driven risk assessment are insufficient to capture the dynamic and often silent progression of electrical instability in these populations. This narrative review evaluates the emerging role of artificial intelligence (AI)-enabled sensor technologies in remote arrhythmic monitoring of genetically defined cardiomyopathy cohorts. Wearable ECG devices, implantable cardiac monitors, multisensor cardiac implantable electronic device algorithms, pulmonary artery pressure sensors, and contact-free systems enable continuous acquisition of electrophysiological and hemodynamic data, generating digital biomarkers that may reflect early arrhythmic vulnerability and subclinical decompensation. AI-driven analytics enhance signal processing, automated event detection, and remote data triage, with the potential to reduce clinical workload while preserving diagnostic sensitivity. However, current evidence predominantly derives from heterogeneous heart failure or general arrhythmia populations, and prospective validation in genotype-specific cohorts remains limited. Key challenges include algorithm generalizability, signal quality in ambulatory environments, data governance, interpretability of AI models, and integration into structured remote-care pathways. The convergence of genotype-informed risk stratification and multimodal AI-enabled sensing represents a promising strategy to transition from reactive device-based protection to proactive, precision-guided arrhythmic prevention. Dedicated genotype-focused studies and standardized digital endpoints are required to support safe and effective implementation in inherited cardiomyopathies.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Cardiology Unit, Policlinico Universitario Campus Bio-Medico, Via Alvaro del Portillo 200, 00128 Rome, Italy.
- Research Unit of Cardiovascular Science, Department of Medicine and Surgery, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo 21, 00128 Rome, Italy.
ORCID-Profile: Nardi Tetaj, Andrea Segreti, Francesco Piccirillo
Zitieren
APA
Tetaj, N., Segreti, A., Piccirillo, F., Ferro, A., Ligorio, V., Spagnolo, A., Pelullo, M., Crispino, S. P., & Grigioni, F. (2026). AI-Enabled Sensor Technologies for Remote Arrhythmic Monitoring in High-Risk Cardiomyopathy Genotypes. Sensors, 26(7), 2078. https://doi.org/10.3390/s26072078
Vancouver
Tetaj N, Segreti A, Piccirillo F, Ferro A, Ligorio V, Spagnolo A, et al. AI-Enabled Sensor Technologies for Remote Arrhythmic Monitoring in High-Risk Cardiomyopathy Genotypes. Sensors. 2026;26(7):2078. doi:10.3390/s26072078
BibTeX
@article{Tetaj2026,
author = {Tetaj, Nardi and Segreti, Andrea and Piccirillo, Francesco and Ferro, Aurora and Ligorio, Virginia and Spagnolo, Alberto and Pelullo, Michele and Crispino, Simone Pasquale and Grigioni, Francesco},
title = {AI-Enabled Sensor Technologies for Remote Arrhythmic Monitoring in High-Risk Cardiomyopathy Genotypes},
journal = {Sensors},
year = {2026},
volume = {26},
number = {7},
pages = {2078},
doi = {10.3390/s26072078}
}
EUVIMED