EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Rapid Detection and Quantification of DMNB Vapors Using a Handheld Ion Mobility Spectrometer Operated near Ambient Temperature

Victor Bocoș-Bințințan iD, Tomáš Rozsypal iD, Alin-Gabriel Moraru iD, Maria-Paula Bocoș-Bințințan iD, Adrian Pătruț iD, Petrișor Pătrașcu iD

Sensors · 25.03.2026 · 26 (7) · 2047

DOI: 10.3390/s26072047 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 25.03.2026. Verfasst von Victor Bocoș-Bințințan und 5 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Environmental Science & Engineering, Babeș-Bolyai University, Str. Fântânele nr. 30, 400294 Cluj-Napoca, Romania. Die Arbeit nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The detection of plastic explosives in vapor form is extremely challenging due to the very low volatility of their primary components, such as RDX and PETN. To overcome this limitation, volatile chemical markers like 2,3-dimethyl-2,3-dinitrobutane (DMNB) are added to explosive formulations to enable indirect vapor detection. This study presents a rapid method for detecting and quantifying DMNB vapors using a handheld ion mobility spectrometer (IMS) operating near ambient temperature, ammonia-doped and equipped with a non-radioactive corona discharge ionization source. The instrument, model LCD-3.2E (Smiths Detection Ltd.), is based on a twin drift–cell time-of-flight configuration and simultaneously records ion mobility spectra in both positive and negative modes. DMNB generated distinct product ion peaks in both modes, with reduced mobility values (K0) of 1.42 cm2V−1s−1 (positive) and 1.37 cm2V−1s−1 (negative). The method demonstrated high sensitivity, with limits of detection calculated at 1.4 ppbv (10.2 × 10−3 mg m−3) in positive mode and 3.1 ppbv (22.7 × 10−3 mg m−3) in negative mode. The IMS system provided rapid responses within seconds and covered a quantifiable concentration range of 5–3000 ppbv, with saturation estimated to appear above approximately 5 ppmv (36.6 mg m−3). The simultaneous dual-polarity response of the DT IMS enhances both the selectivity and reliability of identification. These findings confirm the capability of portable IMSs for fast trace vapor detection in DMNB, supporting its application in field-based screening scenarios such as luggage inspection or container interrogation, where indirect detection of plastic explosives is required.

Schlagwörter

Stichwörter der Autor:innen

2,3-dimethyl-2,3-dinitrobutane (DMNB)ICAO markersion mobility spectrometryplastic explosivestrace detection

Autor:innen und Institutionen

  • Faculty of Environmental Science & Engineering, Babeș-Bolyai University, Str. Fântânele nr. 30, 400294 Cluj-Napoca, Romania.
  • SC Transcend SRL, Str. Arinilor nr. 13, 400568 Cluj-Napoca, Romania.
  • Nuclear, Biological and Chemical Defence Institute, University of Defence, Vita Nejedleho 1, 68201 Vyskov, Czech Republic.
  • Faculty of Veterinary Medicine, University of Agricultural Sciences and Veterinary Medicine, Calea Mănăştur 3-5, 400372 Cluj-Napoca, Romania.
  • Faculty of Chemistry & Chemical Engineering, Babeș-Bolyai University, Str. Arany János nr. 11, 400028 Cluj-Napoca, Romania.
  • Raluca Ripan Institute for Research in Chemistry, Babeș-Bolyai University, Str. Fântânele nr. 30, 400294 Cluj-Napoca, Romania.

ORCID-Profile: Victor Bocoș-Bințințan, Tomáš Rozsypal, Alin-Gabriel Moraru, Maria-Paula Bocoș-Bințințan, Adrian Pătruț, Petrișor Pătrașcu

Zitieren

APA

Bocoș-Bințințan, V., Rozsypal, T., Moraru, A. G., Bocoș-Bințințan, M. P., Pătruț, A., & Pătrașcu, P. (2026). Rapid Detection and Quantification of DMNB Vapors Using a Handheld Ion Mobility Spectrometer Operated near Ambient Temperature. Sensors, 26(7), 2047. https://doi.org/10.3390/s26072047

Vancouver

Bocoș-Bințințan V, Rozsypal T, Moraru AG, Bocoș-Bințințan MP, Pătruț A, Pătrașcu P. Rapid Detection and Quantification of DMNB Vapors Using a Handheld Ion Mobility Spectrometer Operated near Ambient Temperature. Sensors. 2026;26(7):2047. doi:10.3390/s26072047

BibTeX
@article{BocoBininan2026,
  author = {Bocoș-Bințințan, Victor and Rozsypal, Tomáš and Moraru, Alin-Gabriel and Bocoș-Bințințan, Maria-Paula and Pătruț, Adrian and Pătrașcu, Petrișor},
  title = {Rapid Detection and Quantification of DMNB Vapors Using a Handheld Ion Mobility Spectrometer Operated near Ambient Temperature},
  journal = {Sensors},
  year = {2026},
  volume = {26},
  number = {7},
  pages = {2047},
  doi = {10.3390/s26072047}
}
Kostenlos starten →